Step 1

Remove Von Duprin installed mechanical dogging assembly.

VON DUPRIN MECHANICAL DOGGING ASSEMBLY

ELECTRICAL DATA 24VDC @ 700/200mA RED (+) BLK (-) PATENT #8,851,530

Disconnect vertical rods from the Device head

NOTE Retro-Fitting Vertical Rod Devices:

Before retro-fitting an electric latch assembly into a vertical device, the following must be done to ensure proper alignment. Disconnect the vertical rods from the device head. Install the electric latch assembly as shown above. Once the ELR is properly installed energize it so that the push pad is dogged down, by doing so it will allow for proper alignment for the vertical rods. Finally reconnect the vertical rods to the device and make the proper adjusments.

INSTALLATION INSTRUCTIONS LR100VDK-22 ELECTRIC LATCH RETRACTION DEVICE KIT VON DUPRIN MODELS 22 & 2227 36-48 INCH OPENING ima

INSTALLATION INSTRUCTIONS LR100VDK-22 ELECTRIC LATCH RETRACTION DEVICE KIT VON DUPRIN MODELS 22 & 2227 36-48 INCH OPENING dia

INSTALLATION INSTRUCTIONS LR100VDK-22 ELECTRIC LATCH RETRACTION DEVICE KIT VON DUPRIN MODELS 22 & 2227 36-48 INCH OPENING ima

INSTALLATION INSTRUCTIONS LR-1VD CONNECTING ROD FOR USE ON VON DUPRIN DEVICES LESS DOGGING FEATURE

When retrofitting to existing vertical rod devices, adjustment of the rods are required for proper assembly of the LR100VDK Kit. Please see the SDC website (www.sdcsecurity.com) for installation tips and photographs of installing.

  • 1. Remove the rail and push pad from the device
  • 2. Drill a 5/32" (.156") diameter hole as shown in illustration.
  • 3. Insert the connecting rod provided and fasten in screw