iu_minitech_easy_02_eng
Open the original PDF document
View PDF
MiniTech
User instructions
Default codes
Master 1 2 3 4 5 6 7 8
Manager 0 1 - 1 2 3 4 5 6 + Optional Dallas key User 2 0 2 - 0 2 0 2 0 2 + Optional Dallas key User 3 0 3 - 0 3 0 3 0 3 + Optional Dallas key User x x x – x x x x x x + Optional Dallas key
Dallas key
In the event that the user is composed of "code + Dallas key", before or after entering the code, the Dallas key must be placed on the appropriate Dallas key reader.
Override users
Override users open without waiting the time delay. In the default programming they are set in dual code opening but, upon request, the single opening mode can also be set.
Silent alarm
It is activated by increasing or decreasing the last digit by one number when entering the opening code.
Penalty
After four attempts to enter an incorrect code, the lock starts a 4-minute delay period. Each attempt to enter the code within the 4 minutes delay period restarts the count.
Low battery warning
A message on the display and a long beep during opening indicates a low battery level. Replace immediately the low battery with a new Alkaline battery.
Sound signals
A double beep normally indicates a correct operation. A long beep indicates an incorrect operation and the end of the operation itself.
Reccomendations
Do not use easily identifiable codes such as 123456, dates of birth or other personal information.
Opening (It is recommended to change the factory code before use and to safely store the new code)
Press any key to turn on the device. The display shows the message: USER CODE
Enter the opening code. The display shows the time delay counting if programmed. TIME DELAY
At the end of the time delay, the display shows the counting of the open window. OPEN WINDOW
Enter the opening code. The display shows the message: OPEN
Open the safe door within 4 seconds.
Dual code opening (It is recommended to change the factory code before use and to safely store the new code)
Press any key to turn on the device. The display shows the message: USER CODE
Enter the opening code. The display shows the time delay counting if programmed. TIME DELAY
At the end of the time delay, the display shows the counting of the open window. OPEN WINDOW
Enter the 1° opening code. The display shows the message: 2° USER CODE
Enter the 2° opening code. The display shows the message: OPEN WINDOW
Open the safe door within 4 seconds.
Change code ( Safely store the new code and perform various opening / closing tests before closing the safe door )
To be performed with the door open!
Press and hold . The display shows the message:
Enter the old code . The display shows the message: NEW CODE
Enter the new code . The display shows the message: CONFIRM CODE
Confirm the new code . OPERATION
Perform various opening / closing tests before closing the safe door.
X X – X X X X X X 00:59 00:01
X X – X X X X X X
00:59
00:01
X X – X X X X X X
OLD CODE X X - X X X X X X X X X X X X X X X X X X DONE
User instructions
MiniTech
Users management Press and hold . The display shows the message: USERS MANAGEMENT 0 1 – X X X X X X Enter the Manager code. Press to scroll the list or enter the user ID. 02 03 04 05 06 x _ _ "" installed user, "X" deleted user, "_" disabled user. The override users (50 – 59) can be installed only when the lock is open. Press . If the user is not installed, the display shows the message: 02 INSTALL? Press to confirm, or to disable/enable/delete and to confirm. Membrane test Press any key to turn on the device. Press and hold the button . The display shows the message: MEMBRANE TEST 1234567890 Press in sequence the buttons shown in the display. MEMBRANE TEST 1234567890 A confirmation beep is given for each pushed key working properly. A damaged key is indicated with a long beep. The display shows the message: WRONG/FAULTY KEY Change date and time Press (or press and hold) . The display shows the message: MENU MASTER X X X X X X X X Enter the Master code. The display shows the message: TIME AND DATE SETTINGS Press . The display shows the date and time currently set: 12:00 WED 13 /02/2019 To modify, press . The display shows the message: hh:mm _ _ _ DD/MM/YYYY Enter time and date and press to confirm. Block system Press and hold . The display shows the message: BLOCK SYSTEM X X - X X X X X X Enter the code authorized for the block operations. The display shows the message: BLOCK UNTIL DD/MM hh:mm Enter reopening date and time (max. 31 days). BLOCK UNTIL
Further information
For the complete manual and further information on the product's features, please visit www.tecnosicurezza.it
Tecnosicurezza SpA Tecnosicurezza Inc. Tecnosicurezza Sa
Press to confirm. The display shows the message:
37057 San Giovanni Lupatoto Tel.+39 045 826 64 70 Tel.+1 859 490 89 30 Tel.+34 91 804 33 91 Fax. +39 045 826 64 69 Fax.+34 91 804 32 63 info@tecnosicurezza.it info@usatecno.com info@tecnosicurezza.es
Press to confirm. The display shows the message: BLOCK THE LOCK?
Verona Versailles, KY 40383
GLOBAL HEADQUARTERS USA HEADQUARTERS SPAIN HEADQUARTERS
Via Cesare Battisti. 276 50, Thomas Lane C/Menor, 4 - Nave 10 Pol. Ind La Mina 28770 Colmenar Viejo
13/02 12:00
LOCK BLOCKED