SHEET T30904-3 1 of 2 T30904-2 1-02 DO NOT SCALE DRAWING SUPERSEDES TEMPLATE NO. DATE

681F77 Top Strike Preparation (See Note 6) Dust Cover Reinforcements (By Frame Manufacturer) 1(25)min. -By Frame Manufacturer 1(25) Min. (30.2)3/32 RHR Door <u>3/4</u> (2.4) LHR Door (19) Inside Face Inside Face 1-1/2 (38.1)Latch & Latch & Strike Strike EVERTICAL REFERENCE 11/16 RHR Door Bevel C (17.5)(or square edge of door) LHR Door Bevel (or square edge of door) For Door Prep See Sheet 1 10-32 TAP (2 Places) 2-1/16 2-1/16 (52)(52)1-5/8 CUTOUT (41.3)(51)15/16(24) (Note 9) ะค Latch, Strike & Plane of Section Shown Above Notes:

  • 1. Do not scale drawing.
  • 2. Dimensions are in inches (mm).
  • 3. Preparation is typical for both hands.
  • 4. Minimum door stile width: 4-1/2 (114).
  • 5. Prepare mounting holes when installing the device.
  • Drawing shows elevation (frame bisected on strike center), bottom view looking up and side view.
  • Provide adequate structural support to maintain door integrity after device installation with power tools, door use, or abuse.
  • 8. For recommended door reinforcements see template T30800.
  • Door located in frame for door silencers. If not used, compensate this dimension to seat the door against the stop without rattle.
  • 10. Device mount to hinge stile (not shown) requires hole location and preparation during device installation.

  • 11. For outside trim preparation see appropriate trim template.
  • For electrical devices (suffixes M91, M92, M93, M94, M97) also see template T30890.
  • 13. Holes for optional SNB (Required for unreinforced doors): 9/32 (7.00) dia., inside door face; 3/8 (9.50) dia., outside door face.
  • Maximum thickness 5/32 (4.0) when outside escutcheon trim is used.
  • 15. Bottom bolt should retract to 1/8 (3.2) above floor strike. Floor coverings in the door path must be laid accordingly.

ED5860 & ED5860B Series Concealed Vertical Rod Exit Devices with Optional SO9 Floor Strike

Application for Metal Door and Frame Without Threshold

Corbin Russwin ED5860(B) Wide Stile CVR S09 Floor Strike Metal Door and Frame without Threshold Template_T30904 image on page

www.corbinrusswin.con

SUPERSEDES T30904-2 DO NOT SCALE DRAWING

ATE NO. T30904-3 SHEET 2 of 2 DATE 1-02