← Corbin
Notes:
- 1) Do not scale drawing.
- 2) Dimensions are in inches(mm).
- 3) LHR active pair shown. Preparation is typical for both hands.
- 4) Minimum door stile width: 3-1/2 (89).
- 5) Prepare mounting holes when installing the device.
- 6) For square door edges, or other center clearance, compensate locating dimensions as required to maintain strike to device distance shown.
- 7) For trim preparation see appropriate trim template.
- 8) Provide adequate structural support to maintain door integrity after device installation with power tools, door use, or abuse.
- 9) Device mount to hinge stile (not shown) requires holes location and preparation during device installation. Door structural requirements are similar for both door stiles.
- 10) For electrical devices (suffixes M91, M92, M93, M94, M97) also see template T30890.
- 11) Wood screws (by others) permitted in solid core wood doors if pilot holes are used for installation. Device:#14x1-1/4"; Strike:#10x1-1/4".
ED4200M Series Rim Exit Devices Optional S02 Strike and SNB
Application to Pair of Wood or Composite Doors without Mullion (Not for Fire Labeled Devices)
05-09 DO NOT SCALE DRAWING SUPERSEDES TEMPLATE NUMBER DATE www.corbinrusswin.com ASSA ABLOY T31092