MOUNTING INFORMATION
Sex nuts or through bolts are required for wood and plastic covered composite doors, and any type of door without reinforcements and recommended for wood core and metal clad (Kalamein) type doors.
offset pivots, or center pivots. 2. Dimensions given in inches and (mm).
4. Auxiliary door stop required, by others.
Application
NON
A.D.A
3. Minimum Top Rail: 2 (51)
1. Dimensions "A" & "B" apply to centerline of hinge/pivot for butt hinges.
A
Drop Plate
7-1/4
(184)
В
Soffit Bracket
11-5/8
(295)
C
27-1/2
(699)
NOTES:
MAXIMUM
OPENING
90°
RH SHOWN LH OPPOSITE
Closer To Be Installed In A True Horizontal CAUTION: Position To Ensure Proper Closer Performance.
MOUNTING SCREW SPECIFICATIONS
ARM AND QUIK-INSTALL™ BRACKET #1/4-14 self-drilling screw. 1/8 (3) diameter pilot hole Sex nuts, furnished required for Wood when ordered Applications. 1-21/32 (42)1/4-20 THREAD 3/8 9/16 DIA.
(10)(14)
RESPONSIBILITY
DOOR AND FRAME MANUFACTURERS ARE RESPONSIBLE FOR PROVIDING ADEQUATE CONSTRUCTION OR REINFORCEMENTS FOR PROPER INSTALLATION OF HARDWARE SHOWN. ALL ARCHITECTURAL BUILDERS HARDWARE MUST BE INSTALLED ON PROPERLY REINFORCED DOORS AND FRAMES, REGARDLESS OF TYPE, MATERIAL OR METHOD OF CONSTRUCTION
DC6210 Series x A3 x597F58/188F65 DC6410 Series x A3 x 597F58/188F65
Heavy Duty Parallel Arm Mounted Surface Door Closer with 597F58/188F65 Drop Plate
ASSA ABLOY www.corhinrusswin.com
SUPERSEDES DO NOT SCALE DRAWING T31112 TEMPLATE NUMBER T31112-1 04-10
This Side Only (4 Places)