NOTES:

  • 1. Do not scale drawing.
  • 2. Blocking in wood frames must be securely fastened to header to support closer body.
  • 3. Hollow-metal doors require channel or box-type reinforcement when through-bolt mount is specified.
  • 4. Minimum thickness recommended for reinforcements in hollow-metal doors and frames: .1046" [2.66mm] unless otherwise noted.
  • 5. Max. degree of opening: 140° [conditions permitting].
  • 6. Right hand door shown, Left hand opposite.
  • 7. Minimum ceiling clearance for closer cover: 3-1/2" [88.9 mm]
  • 8. To install the closer on a frame that is greater than 3" [76.2mm] without the 754F80 Drop Plate, refer to template T31276, available for download from CorbinRusswin.com.
  • 9. All dimensions in inches [mm].

*Minimum Ceiling Height

DC5200 Cam Action Door Closer, Pull Side Application, with 2888 Backplate Frame Mounted; Frame Face Less than 3" [76.2mm]

TEMPLATE NUMBER REV

1 DATE T31278 10/23