← Corbin
NOTES:
- 1. Do not scale drawing.
- 2. Blocking in wood frames must be securely fastened to header to support slide track assembly.
- 3. Hollow-metal doors require channel or box-type reinforcement when through-bolt mount is specified.
- 4. Minimum thickness recommended for reinforcements in hollow-metal doors and frames: .1046" [2.66mm] unless otherwise noted.
- 5. Max. degree of opening: 140° (conditions permitting).
- 6. Right hand door shown, Left hand opposite.
- 7. Minimum ceiling clearance for slider track assembly: 1-1/2" [38.5 mm]
- 8. All dimensions in inches [mm].
*Minimum Ceiling Height
DC5200 Cam Action Door Closer Pull Side Application, Door Mounted
TEMPLATE NUMBER REV DATE
T31277 1 10/23
Approved 2023-10-10