MOUNTING INFORMATION
Sex nuts or through bolts are required for wood and plastic covered composite doors, and any type of door without reinforcements and recommended for wood core and metal clad (Kalamein) type doors.
RH SHOWN OPPOSITE
| TEMPLATE CROSS REFERENCE | |
|---|---|
| DESCRIPTION | TEMPLATE |
| DC3210, DC3610 | T30612 |
| DC3210, DC3610 x M80 | T30613 |
| DC3210, DC3610 x M80 & M83 | T30616 |
| DC3210 DC3610 v MB3 | T30615 |
NOTES:
.... TO OBTAIN EXTRA CLOSING FORCE, ADO 3"(76.2)TO DIMENSIONS MARKEO BY ASTERISK(米). THIS WILL LIMIT DEGREE OF OPENING TO 110°.
DIMENSION A DESCRIPTION DC3610 10-3/8 (263.5) DC3210 11-5/8 (295.3) FULL COVER
- DIMENSIONS GIVEN IN INCHES AND (MM).
- ₹. MINIMUM TOP RAIL: 4-1/16 (103.2) STANDARD DOOR 4-3/8 (111.1) RABBETED DOORS
CAUTION: CLOSER TO BE INSTALLED IN A TRUE HORIZONTAL POSITION TO ENSURE PROPER CLOSER PERFORMANCE
DIMENSIONS MARKED (*) APPLY TO CENTERLINE OF HINGE/PIVOT FOR BUTT, SWING CLEAR, OFFSET AND CENTER HUNG PIVOTS. FLUSH MAXIMUM DEGREE OF OPENING FOR SWING CLEAR HINGE IS 110°. MUSUARI FRAME E INNER 1-9/16 MOUNTING (39.7)7/8 MAX SCREWS 1-21/32 (42.1)-FDR 1-3/4 (44.5) 2-3/16 INCH DOORS (55.6 (LENGTH MAY VARY FOR OTHER DOOR THICKNESSES) 15/16 (23.8)DOOR RIG RVE 9/16 DIA (9.5)2-3/4 (14.3)FLUSH TRANSOM 1-1/2 (69.9) BRACKET (M82) SEX NUT DETAIL (38.1) RABBETED DOOR APPLICATION 5/8 (15.9)5/8 4-1/2 (15.9)* 6-1/B (114.3) FLUSH 3/8 (155.6) TNNFR TRANSOM (9.5)15/16 MOUNTING (6.4)FRAME (23.8) SCREWS ᡠᢆᢩ᠊ Ф-1/4-20 TAP FOR MACHINE SCREW £ HINGE OR DRILL FOR #14 WOOD SCREW US SIAUL (8 PLACES) 3/16 (4.8)2-3/4 5/8 _(15.9 * 7-1/2 MAX (69.9) П (190.5) MAX FLUSH TRANSOM BRACKET (M82) 2 (25.4) (50.8) 1/2 (12.7) 3 (76.2)SEX NUT APPLICATION: 4-5/169/32 DIA. (7.1) THRU CLEARANCE FOR 1/4-20 SEX NUT APPLICATION: -(109.5)ENLARGE TO 3/8 (9.5) DIA. 1-5/16MACHINE SCREW THIS SIDE DNLY FULL COVER (33.3) (4 PLACES) (4 PLACES)
RESPONSIBILITY
Door and Frame Manufacturers are responsible for providing adequate construction or reinforcements for proper installation of hardware shown. All architectural builders hardware must be installed on properly reinforced doors and frames, regardless of the type, material, or method of construction.
DC3210 SERIES ΒY M 8 2 DC3610 SERIES ΒY M 8 2
SURFACE DOOR CLOSER PARALLEL ARM MOUNTING BY FLUSH TRANSOM BRACKET
www.corbinrusswin.com NOT SCALE DRAWING SUPERSEDES
K J TEMPLATE NUMBER
5/7/93