Trine EN Series Fail Safe Fail Secure Field Adjustment Installation Instructions
Open the original PDF document
View PDF
EN SERIES ELECTRIC STRIKES
Fail Safe / Fail Secure Field Adjustment (on DC units only)
All operations are performed with the strike in the upright position *When a unit changed to Fail Safe, the fire rating is eliminated.*
(B) Remove back cover &coil assembly. (A) Screws, remove coil assembly screw. shown. (3-screws). Remove 2 back case 1) Remove the back cover and coil as
latch pin & latch. 2) Insert assembly pin (provided) to remove Note: The slider should fall (remove) slider & slider guard. thru the strike body after latch is removed
Fail Secure
in case with very loose fit.
Note: Tabs of slider guard must fall into slots of strike. Position slider guard as shown. reverse its ends. Determine handing, and top
3) Remove the slider from the frame and
Safe Fail
into slots) (tabs must go Slider Guard Position
back of case. shown. Hold slider in position with finger from 5)Align slider tabs under slider guard, as
the top, fail safe side up (as shown). slider guard in position insert slider from the fail safe end up by the coil. With 4) Place the slider back in the frame with
the case as shown. the spring tail goes thru the hole in the side of 6) Roll the Latch back into cavity making sure
Fail Safe Indication
sure the slider can move up & down freely. 8) Check the action of the slider to make
Note: Position wires thru slot toward front of
brackets of coil assembly.
Note:
9) Replacing coil assembly.
Slider must be in position between
free to move up & down with no resistance. 10) Check slider action. Make sure slider is
tighten. Replace back cover: Replace 2 screws and 11) Thread wires thru cover as shown.
Bronx,NY 10461 1440 Ferris Place
FAX:718-829-6405 TEL:718-829-2332
customerservice@trineonline.com