Techmaster User Instructions II
Open the original PDF document
View PDF
TechMaster
User instructions
Default codes
Master 1 2 3 4 5 6 7 8
Manager 0 1 - 1 2 3 4 5 6 + Optional Dallas key User 2 0 2 - 0 2 0 2 0 2 + Optional Dallas key User 3 0 3 - 0 3 0 3 0 3 + Optional Dallas key User x x x – x x x x x x + Optional Dallas key
Dallas key
In the event that the user is composed of "code + Dallas key", before or after entering the code, the Dallas key must be placed on the appropriate Dallas key reader.
Override users
Override users open without waiting the time delay. In the default programming they are set in dual code opening but, upon request, the single opening mode can also be set.
Silent alarm
It is activated by increasing or decreasing the last digit by one number when entering the opening code.
Penalty
After four attempts to enter an incorrect code, the lock starts a 4-minute delay period. Each attempt to enter the code within the 4 minutes delay period restarts the count.
Low battery warning
A message on the display and a long beep during opening indicates a low battery level. Replace immediately the low battery with a new Alkaline battery.
Sound signals
A double beep normally indicates a correct operation. A long beep indicates an incorrect operation and the end of the operation itself.
Reccomendations
Do not use easily identifiable codes such as 123456, dates of birth or other personal information.
Opening (It is recommended to change the factory code before use and to safely store the new code)
Press any key to turn on the device. The display shows the message: USER CODE
Press to open with Manager code or go to the next step.
Enter the opening code. The display shows the time delay counting if programmed. TIME DELAY
At the end of the time delay, the display shows the counting of the open window. OPEN WINDOW
Enter the opening code. The display shows the message: OPEN
Open the safe door within 4 seconds.
Dual code opening (It is recommended to change the factory code before use and to safely store the new code)
Press any key to turn on the device. The display shows the message: USER CODE
Press to open with Manager code or go to the next step.
Enter the opening code. The display shows the time delay counting if programmed. TIME DELAY
At the end of the time delay, the display shows the counting of the open window. OPEN WINDOW
Enter the 1° opening code. The display shows the message: 2° USER CODE
Enter the 2° opening code. The display shows the message: OPEN WINDOW
Open the safe door within 4 seconds.
| X X – X X X X X X | |
|---|---|
|
MANAGER
X X X X X X |
|
| 00:59 | |
| 00:01 | |
| X X – X X X X X X |
|---|
|
MANAGER
X X X X X X |
| 00:59 |
| 00:01 |
| X X – X X X X X X |
User instructions
TechMaster
|
Change code ( Safely store the new code and perform various opening / closing tests before closing the safe door )
To be performed with the door open! |
|||
|---|---|---|---|
|
Press and hold
. The display shows the message: |
OLD CODE
X X - X X X X X X |
||
|
To change the Manager code press
twice. The display shows the message: |
CHANGE
MANAGER CODE |
||
| Enter the old code. The display shows the message: |
NEW CODE
X X X X X X |
||
| Enter the new code. The display shows the message: |
CONFIRM CODE
X X X X X X |
||
| Confirm the new code. |
OPERATION
DONE |
||
| Perform various opening / closing tests before closing the safe door. | |||
| Users management | |||
|
Press
and then . The display shows the message: |
MANAGER MENU
X X X X X X |
||
|
Enter the Manager code and scroll through the submenus with
until Users management. Press to access. |
USERS MANAGEMENT | ||
|
Press
to scroll the list or enter the user ID. |
02 03 04 05 06
x _ _ |
||
| "" installed user, "X" deleted user, "_" disabled user. | |||
| Overrides users can be installed only when the lock is open. | |||
|
Press
. If the user is not installed, the display shows the message: |
02
INSTALL? |
||
|
Press
to confirm, or to disable/enable/delete and to confirm. |
|||
| Membrane test | |||
| Press any key to turn on the device. | |||
|
Press and hold the button
. The display shows the message: |
MEMBRANE TEST
1234567890 |
||
| Press in sequence the buttons shown in the display. |
MEMBRANE TEST
1234567890 |
||
| A confirmation beep is given for each pushed key working properly. | |||
| A damaged key is indicated with a long beep. The display shows the message: |
WRONG/FAULTY
KEY |
||
| Change date and time | |||
|
Press (or press and hold)
. The display shows the message: |
MASTER MENU
X X X X X X X X |
||
| Enter the Master code. The display shows the message: |
TIME AND DATE
SETTINGS |
||
|
Press
. The display shows the date and time currently set: |
12:00
WED 13 /02/2019 |
||
|
To modify, press
. The display shows the message: |
hh:mm
DD/MM/YYYY |
||
|
Enter time and date and press
to confirm. |
|||
Further information
For the complete manual and further information on the product's features, please visit www.tecnosicurezza.it
Tecnosicurezza SpA Tecnosicurezza Inc. Tecnosicurezza Sa
Via Cesare Battisti. 276 50, Thomas Lane C/Menor, 4 - Nave 10 37057 San Giovanni Lupatoto Verona Versailles, KY 40383 Tel.+39 045 826 64 70 Tel.+1 859 490 89 30 Tel.+34 91 804 33 91 Fax. +39 045 826 64 69 Fax.+34 91 804 32 63
GLOBAL HEADQUARTERS USA HEADQUARTERS SPAIN HEADQUARTERS
Pol. Ind La Mina 28770 Colmenar Viejo info@tecnosicurezza.it info@usatecno.com info@tecnosicurezza.es