T-ED04039 – Template for 2945 with 4500 RIM Exit Device

Open the original PDF document

View PDF

4 3/8" 111 1 9/16" 40 40" 1016 2 3/16" 56 2 7/16" 62 25/32" 20 DEVICE CL FINISHED FLOOR DEVICECL INSIDE FACE OF DOOR FRAME STOP NOTE 2 NOTE 2 2 1/4" (MIN) 57 NOTE 4 NOTE 4 1/4" [6] 8 1/4" [210] 5/8" [16] (NOTE 7) 2X NOTE 6 11/32" 8 1 9/16" [40] 1 15/16" [49] (NOTE 5) 1/4" [16] 4 1/8" [105] 2X 1/8" (NOTE 8) 7 11/16" [195] FRAME STOP STRIKE FRAME SPACER NOTES: 1. LHR door shown. Preparation is typical for both door hands. 2. Please see 4500 Series Rim Exit Device Installation Instructions (I-ED00789 and T-ED00043) for sizing. 3. Exit device must be installed first before 2945 strike. 4. Provide door stiffeners as needed to prevent door collapse due to installation with power tools, door use, or abuse. 5. This is a nominal dimension and is measured to the door face. Mount the exit device then mount the strike to proper centerline. Ensure the dead latch is in the proper position and does not fall into the strike. 6. These holes are pilot holes. Thread with 1/4"-20 tap. 7. Wire hole position will change in relation to the strike center line based on device handing. 8. These are Pilot holes for spacer mounting Hardware. 9. Spacer Center Line matches Strike Center line. STRIKE PREPARATION DETAIL FACE OF DOOR STRIKE CL DEVICECL DOOR 4500 RIM DEVICE WITH 2945 DOOR PREP TEMPLATE APPLICATION FOR METAL AND WOOD DOORS (FOR PANIC AND FIRE RATED DEVICES)

DRAWING NO: T-ED04039 REV: 01 REV DATE: 22JAN2025 SHEET 1 OF 1 HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 - (800) 325-9995 - Fax (800) 782-0149