e*Tag® ET8-RO-W-D Installation Instructions

Installation Steps for Decorator Reader

  • 1. This reader is designed for installation using a standard, single-gang electrical box or trim ring.
  • 2. Splice reader wires to cable that has been home run to the access control panel (see wiring color chart) and trim unused wire ends. (Violet, gray, yellow and blue wires are often not used.) Push splices into the box.
  • 3. Attach the reader to the box mounting tabs with the 6-32 screws provided.
  • 4. Install the cover plate with the screws that are provided in the package.

SPECIFICATIONS:

POWER REQUIREMENTS

5-14 VDC; Idle: 30 mA, When reading card: 65mA

INPUTS & OUTPUTS

Wiegand Output Sink Current 100mA Wiegand Output Source Current 5mA

LED Bi-color (Red or Green) Buzzer & Hold Ground to Activate

Cable Distance 500 ft.

Cable Type 6-8 Conductor, 18-22 AWG

ENVIRONMENT

Ambient Temperature -40° to +70°C (-40° to +158°F) Humidity 0 to 95% (non-condensing)

COMMUNICATIONS

Wiegand Industry Standard Protocol

"Changes or modifi cations not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment".

Wire Color ET8-RO-W-D
GREEN Wiegand Data 0
WHITE Wiegand Data 1
VIOLET N/A
GRAY N/A
ORANGE Green LED
BROWN Red LED
YELLOW Buzzer
BLUE Hold Line
RED 5-14VDC +
BLACK DC Ground

20301 Nordhoff Street • Chatsworth, CA 91311 phone 818-882-0020 • fax 818-882-7052

TOLL-FREE (800) 891-0020 Web site: www.securakey.com

3322058 6826

FCC Warning: This device complies with Part 15 of the Class B FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. And (2) this device must accept any interference received, including interference that may cause undesired operation. This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.