Pulse Pro User Instructions I
Open the original PDF document
View PDF
Pulse Pro
User instructions
Default codes
Manager 6 0 - 1 2 3 4 5 6 + Optional Dallas key User 2 0 2 - 0 2 0 2 0 2 + Optional Dallas key User 3 0 3 - 0 3 0 3 0 3 + Optional Dallas key User x x x – x x x x x x + Optional Dallas key
Dallas key
In the event that the user is composed of "code + Dallas key", before or after entering the code, the Dallas key must be placed on the appropriate Dallas key reader.
Override user
The override users open without waiting the time delay. In the default programming they are set in dual code opening but, upon request, the single opening mode can also be set.
Silent alarm
It is activated by increasing or decreasing the last digit by one number when entering the opening code.
Penalty
After four attempts to enter an incorrect code, the lock starts a 4-minute delay period. Each attempt to enter the code within the 4 minutes delay period restarts the count.
Low battery warning
A long beep during opening indicates a low battery level.
Replace immediately the low battery with a new Alkaline battery.
Sound signals
A double beep normally indicates a correct operation. A long beep indicates an incorrect operation and the end of the operation itself.
Recommendations
Do not use easily identifiable codes such as 123456, dates of birth or other personal information.
Opening (It is recommended to change the factory code before use and to safely store the new code)
Enter the opening code (default Manager code 60-123456).
If the code is correct, the keypad will beep twice.
If programmed, the time delay count starts. The LED flashes every 2 seconds.
A beep every 2 seconds indicates the end of the time delay count.
Enter the opening code. The keypad beeps twice.
Open the safe door within 4 seconds.
Dual code opening (It is recommended to change the factory code before use and to safely store the new code)
Enter the opening code (default Manager code 60-123456).
If the code is correct, the keypad will beep twice.
If programmed, the time delay count starts. The LED flashes every 2 seconds.
A beep every 2 seconds indicates the end of the time delay count.
Enter both opening codes . The keypad beeps twice.
Open the safe door within 4 seconds.
Change code (Safely store the new code and perform various opening / closing tests before closing the safe door)
To be performed with the door open!
Press and hold until the double beep. The LED remains on.
Enter the ID of the user whose code is to be changed.
Enter the old code .
Enter the new code .
Confirm the new code .
Perform various opening / closing tests before closing the safe door.
PulsePro
| Activate a new user | |
|---|---|
|
Press and hold
until the double beep. The LED remains on. |
|
| Enter the Manager code. The keypad beeps twice. | |
|
Enter the ID of the user to be installed.
If the user is available, the keypad beeps twice. |
|
| Enter the code to be associated with the user (and the Dallas key if necessary). | |
| Enter again the code to confirm it (and the Dallas key if necessary). | |
| Disable/Enable users (Function not available if the dual code opening is activated) | |
|
Press and hold
until the double beep. The LED remains on. Enter the Manager code. The keypad beeps twice. |
|
|
All users are disabled/enabled.
Delete an user |
|
|
Press and hold
until the double beep. The LED remains on. Enter the Manager code. The keypad beeps twice. |
|
|
Enter the ID of the user to be deleted.
The keypad beeps twice. The user is deleted. |
|
| Membrane test | |
|
Press and hold
until the double beep. The LED remains on. |
|
|
Enter the folowing sequence of keys:
At the end the LED turns off. |
|
| A damaged key is indicated with a long beep. | |
|
ERC (Emergency Rescue Code)
If the function is available, allows to perform an emergency opening in case of loss of all the opening codes. |
|
|
Press and hold
until the double beep. The LED remains on. |
|
|
Enter the ERC code (98 – X X X X X X X X ). The LED flashes.
Lock has been restored with the standard codes. |
|
| Time delay (Time Delay programmable from 0 to 99 minutes; Open Window from 1 to 19 minutes) | |
|
Press and hold
until the double beep. The LED remains on. |
|
| Enter the Manager code. The keypad beeps twice. | |
| Enter the values for the time delay and the open window in two digits (e.g. 10 and 05). |
Confirm the values for the time delay and the open window in two digits (e.g. 10 and 05).
Attention, the time delay can only be lowered in the open window.
User instructions
PulsePro
Select a configuration (to be performed with the LOCK OPEN!)
Press and hold until the double beep. The LED remains on. If in pre-setup mode, skip the next two steps.
Enter the Manager code. The LED flashes.
Enter the Master code. The LED remains on.
Enter the ID of the chosen configuration. The keypad beeps twice. Confirm the ID of the chosen configuration. The keypad beeps twice.
Enter the format of the date (0=day/month/year, 1=month/day/year). The LED flashes.
The keypad beeps twice. The led goes off.
10 USERS
|
Manager
management |
Second
Manager |
Second
Master |
Configuration
number |
|
|---|---|---|---|---|
| 10 Users | - | - | - | 02 |
|
Second
Manager |
Second
Master |
Configuration
number |
Manager
management |
Second
Manager |
Second
Master |
Configuration
number |
||
|---|---|---|---|---|---|---|---|---|
| - | - | - | 02 |
10 Users in dual
code opening |
- | - | - | 04 |
| ✓ | - | - | 12 | ✓ | - | - | 14 | |
| ✓ | ✓ | - | 32 | ✓ | ✓ | - | 34 | |
| ✓ | ✓ | ✓ | 72 | ✓ | ✓ | ✓ | 74 | |
| ✓ | - | ✓ | 52 | ✓ | - | ✓ | 54 | |
| - | ✓ | - | 22 | - | ✓ | - | 24 | |
| - | ✓ | ✓ | 62 | - | ✓ | ✓ | 64 | |
| - | - | ✓ | 42 | - | - | ✓ | 44 |
10 USERS + 1 OVERRIDE USERS
|
Manager
management |
Second
Manager |
Second
Master |
Configuration
number |
|
|---|---|---|---|---|
|
10 Users + 1
Override user |
- | - | - | 01 |
| ✓ | - | - | 11 | |
| ✓ | ✓ | - | 31 | |
| ✓ | ✓ | ✓ | 71 | |
| ✓ | - | ✓ | 51 | |
| - | ✓ | - | 21 | |
| - | ✓ | ✓ | 61 | |
| - | - | ✓ | 41 |
10 USERS + 1 OVERRIDE USER, Dual code opening
|
Manager
management |
Second
Manager |
Second
Master |
Configuration
number |
|
|---|---|---|---|---|
|
10 Users + 1
Override user in dual code opening with all users |
- | - | - | 00 |
| ✓ | - | - | ||
| ✓ | ✓ | - | ||
| - | ✓ | - | ||
|
Second
Manager |
Second
Master |
Configuration
number |
Manager
management |
Second
Manager |
Second
Master |
Configuration
number |
||
|---|---|---|---|---|---|---|---|---|
| - | - | - | 00 |
10 Users + 1
Override user. All users in dual code opening |
- | - | - | 03 |
| ✓ | - | - | 10 | ✓ | - | - | 13 | |
| ✓ | ✓ | - | 30 | ✓ | ✓ | - | 33 | |
| ✓ | ✓ | ✓ | 70 | ✓ | ✓ | ✓ | 73 | |
| ✓ | - | ✓ | 50 | ✓ | - | ✓ | 53 | |
| - | ✓ | - | 20 | - | ✓ | - | 23 | |
| - | ✓ | ✓ | 60 | - | ✓ | ✓ | 63 | |
| - | - | ✓ | 40 | - | - | ✓ | 43 |
PulsePro
50 USERS
|
Manager
management |
Second
Manager |
Second
Master |
Configuration
number |
|
|---|---|---|---|---|
| 50 Users | - | - | - | 07 |
|
Second
Manager |
Second
Master |
Configuration
number |
Manager
managemnt |
Second
Manager |
Second
Master |
Configuration
number |
||
|---|---|---|---|---|---|---|---|---|
| - | - | - | 07 |
50 Users with dual
code opening |
- | - | - | 09 |
| ✓ | - | - | 17 | ✓ | - | - | 19 | |
| ✓ | ✓ | - | 37 | ✓ | ✓ | - | 39 | |
| ✓ | ✓ | ✓ | 77 | ✓ | ✓ | ✓ | 79 | |
| ✓ | - | ✓ | 57 | ✓ | - | ✓ | 59 | |
| - | ✓ | - | 27 | - | ✓ | - | 29 | |
| - | ✓ | ✓ | 67 | - | ✓ | ✓ | 69 | |
| - | - | ✓ | 47 | - | - | ✓ | 49 |
50 USERS+ 10 OVERRIDE USERS
|
Manager
management |
Secondo
Manager |
Secondo
Master |
Configuration
number |
|
|---|---|---|---|---|
|
50 Users + 10
Override users |
- | - | - | 06 |
| ✓ | - | - | 16 | |
| ✓ | ✓ | - | 36 | |
| ✓ | ✓ | ✓ | 76 | |
| ✓ | - | ✓ | 56 | |
| - | ✓ | - | 26 | |
| - | ✓ | ✓ | 66 | |
| - | - | ✓ | 46 |
50 USERS + 10 OVERRIDE USERS, Dual mode opening
|
Manager
management |
Second
Manager |
Second
Master |
Configuration
number |
|
|---|---|---|---|---|
|
50 Users + 10
Override users in dual code opening with all users |
- | - | - | 05 |
| ✓ | - | - | ||
| ✓ | ✓ | - | ||
| - | ✓ | - | ||
|
Second
Manager |
Second
Master |
Configuration
number |
Manager
management |
Second
Manager |
Second
Master |
Configuration
number |
||
|---|---|---|---|---|---|---|---|---|
| - | - | - | 05 |
50 Users + 10
Override users. All users in dual code opening |
- | - | - | 08 |
| ✓ | - | - | 15 | ✓ | - | - | 18 | |
| ✓ | ✓ | - | 35 | ✓ | ✓ | - | 38 | |
| ✓ | ✓ | ✓ | 75 | ✓ | ✓ | ✓ | 78 | |
| ✓ | - | ✓ | 55 | ✓ | - | ✓ | 58 | |
| - | ✓ | - | 25 | - | ✓ | - | 28 | |
| - | ✓ | ✓ | 65 | - | ✓ | ✓ | 68 | |
| - | - | ✓ | 45 | - | - | ✓ | 48 |
Further information
For the complete manual and further information on the product's features, please visit www.tecnosicurezza.it
Tecnosicurezza SpA Tecnosicurezza Inc. Tecnosicurezza Sa
Via Cesare Battisti. 276 50, Thomas Lane C/Menor, 4 - Nave 10 37057 San Giovanni Lupatoto Tel.+39 045 826 64 70 Tel.+1 859 490 89 30 Tel.+34 91 804 33 91 Fax. +39 045 826 64 69 Fax.+34 91 804 32 63
Verona Versailles, KY 40383
info@tecnosicurezza.it info@usatecno.com info@tecnosicurezza.es
GLOBAL HEADQUARTERS USA HEADQUARTERS SPAIN HEADQUARTERS
Pol. Ind La Mina 28770 Colmenar Viejo