8310-806K Remote Key Switch

Installation Instructions

The 8310-806K allows the Electric Auto-Equalizer to be set to one of three modes.

  • OFF the operator will not respond to any input signals.
  • AUTO the operator will respond to input signals and open the door.
  • HOLD OPEN the operator will open the door to 90° and remain there until the key is turned to another position.
  • L NOTE: the key can be removed in any position.

To install:

  • 1a Use stick-on template (provided) and place at desired position. Drill the (2) .116" dia. holes and the (1) 1" dia. hole as shown.
  • 1b Route the 6' wire cable to the operator.
  • 1c Connect the green wire to terminal 21.
  • 1d Connect the black wire to terminal 19.
  • 1e Connect the red wire to terminal 6.
  • 1f Use the key to put the operator in the desired mode.