334 Concealed Switch Endcap Retro Fit Installation Instructions

  • 1a Turn power off.
  • 1b Use 3/32 Allen wrench to remove operator cover.
  • 1c Disconnect the 120V power connector from the printed circuit board.
  • 1d Unplug the 334 end cap power and hold open switches from printed circuit board.
  • 1e Loosen the screws a few turns that hold the 334 end cap to the mounting channel. Don't remove the screws.
  • 1f Remove the 334 end cap.
  • 1g Plug the 334CS end cap power switch into the three pin connector on the power input circuit board.
  • 1h Place the 334CS end cap into position under the two mounting channel screws and tighten.
  • 1i Make sure the 334CS power switch is on.
  • 1j Reconnect the 120V power connector to the printed circuit board. Make sure the operator is functional.
  • 1k Reattach operator cover.
  • 1l Turn power on.