How to Maximize the Pass Time with Alarm Lock Narrow Stile Exit Trim with Jackson 1095 Panic Bar

Open the original PDF document

View PDF

ALARM LOCK

345 Bayview Avenue, Amityville, New York, U.S.A. 11701 For Sales and Repairs 1-800-ALA-LOCK • For Technical Service 1-800-645-9440

Fax: 631-789-3383 • info@alarmlock.com Note: Technical Service is for security professionals only

ALARM LOCK Tech Support

Date: Wednesday, November 24, 2010

Subject: Narrow Stile Exit Trim with Jackson 1095 Panic Bar (Maximize "Pass Time")

Models: Narrow Stile DL1225ET, DL1250ET, DL/PDL1325ET, DL/PDL1350ET Series Exit Trim

This Tech Tip involves a Jackson 1095 panic bar installed within the protected premises, and an above referenced Alarm Lock Narrow Stile exit trim device installed outside.

When a User Code is pressed at the keypad, the Alarm Lock exit trim engages a turnpiece (or knob) for the duration of the programmed Pass Time. This turnpiece / knob must be turned by hand to retract the Jackson 1095 latch, to unlock the door. The latch remains retracted until the turnpiece / knob is turned a second time in the opposite direction to extend the latch, re-locking the door. An issue arises when the Pass Time is of an insufficient duration to allow the unlocking and re-locking steps to take place. In other words, because the turnpiece / knob is only engaged for the duration of the Pass Time, the default Pass Time of 3 seconds is usually insufficient to allow the door to be re-locked. The result, in many cases, requires the User to re-enter their User Code to re-engage the turnpiece / knob, to permit the latch to be re-extended, thus allowing the door to be re-locked.

A workaround is to maximize the Pass Time , allowing users extra time to retract the latch, enter the premises and re-extend the latch without the need to re-enter a User Code.

Keypad programming for Pass Time (DL1200 Series):

  • 1. Press the Master Code (or Manager Code) to enter keypad Program Mode
  • 2. Press ;420; to set the 20 second maximum Pass Time .

Keypad programming for Pass Time (DL1300 Series):

  • 1. Press the Master Code (or Manager Code) to enter keypad Program Mode
  • 2. Press ;54: to set the 15 second maximum Pass Time .

DL-Windows programming for Pass Time (DL1300 Series only):

  • 1. Open the Account and click to select the lock you wish to program.
  • 2. Click the " Feat " ( Features ) button on the toolbar.
  • 3. In the Features screen, click the Options tab.
  • 4. Click the " Pass Time in Seconds " pull-down and set to 15 seconds (options are limited to 3, 10 and 15 seconds).