How do I reset my s&g 6120 safe lock.docx

Open the original PDF document

View PDF

How do I reset my s&g 6120 safe lock?

Use the Management Reset Code to Reset my S&G 6120 Lock?

The Sargent and Greenleaf Management Reset code (MRC) is a 7 digit code. The 2 numbers in the MRC that are separated by a "/" or are in "[]" have to be entered simultaneously – press both numbers at the same time.

Execute the MRC sequence using the following steps:

  • 1. Press * 6 #
  • 2. Now enter the MRC
  • 3. After entering the MRC, press #

You will hear 1 beep for each time the MRC has been executed. (If this is the first time that the MRC has been executed, you will hear only 1 beep.)

EX: *6# 135 0/1 87 #

The Master Code has now been reset to the Factory Default of 123456# Enter the Master Code 123456#, and the lock will open.

This reset code is applicable to the following locks: S&G 6120, 6123, Z02 Locks