HS4 Lock Functions and Platform Descriptions – HS4_LS_Func_Plat_Desc
Open the original PDF document
View PDF
| Platform | SAN | SVN | RFnet | BLUEnet | KS | |
| Description |
Stand Alone Network where the
PPD transfers data between the lock and database. |
Salto Virtual Network is a true
data on card system where the user credentials are updated at online locks and those updates are passed on to the offline locks by the credential. |
Wireless communication using the
ZigBee (IEEE 802.15) energy management protocol and allows real-time control, monitoring and reporting. Provides real-time control for Wide Body, AElement, and GEO locks. |
Bluetooth communication (4.1)
using allows real-time control, monitoring and reporting. Provides real-time control for Mini, AElement, Fusion and NEO locks. Allows users to use their smartphones as their credential. |
Cloud based access control system
designed to give the administrator control from their smartphone, tablet, or PC and without system network requirements. |
|
| Most Commonly Used | where the end user budget is the | where controlled access and audit | when real-time control of openings such as lockdown and monitoring | when the system admin wants to | ||
| examples |
greatest concern
churches that have too many brass keys in circulation |
trails are desired
multi-family and assisted living facilities that want to grant differing access rights and capture event history |
of these openings. |
education facilities, some areas of healthcare facilities, and high
security facilities |
provide remote access to a user
commonly found in retail and rental properties |
|
| Locking Hardware | Environment | |||||
| Wide Body | l | l | l | l | Indoor & Outdoor | |
| Mini | l | l | l | l | Indoor Only | |
| AElement | l | l | l | l | Indoor Only | |
| Fusion | l | l | l | Indoor Only | ||
| GEO | l | l | l | l | Indoor Only | |
| NEO | l | l | l | l | Indoor & Outdoor | |
| Exit Trim | l | l | l | l | l | Indoor & Outdoor |
| Storefront | l | l | l | l | Indoor & Outdoor | |
| Glass Door Lock | l | l | l | l | Indoor Only | |
| Locker Lock | l | l | l | l | Indoor Only | |
| Local Network (Server) - Required Components | ||||||
| Wall Reader | l | |||||
| Control Unit | l | |||||
| Gateways | l | l | ||||
| Nodes | l | l | ||||
| PPD | l | l | l | l | ||
| NCoder | l | l | l | l | ||
| Local Network (Server) Software Modules | ||||||
| SPACE-OPT-0021 | l | |||||
| SPACE-OPT-0033 | l | |||||
| Cloud - Required Components | ||||||
| Wall Reader | l | |||||
| Control Unit | l | |||||
| IQ Hub | l | |||||
| Voucher | l | |||||
| Credentials | ||||||
| Card | l | l | l | l | l | |
| Wristband | l | l | l | l | ||
| Key FOB | l | l | l | l | l | |
| Mobile (iOS & Android) | l | l | ||||
| Infrastructure Design | ||||||
| Users | 4 Million | Unlimited | ||||
| Openings | 65,000 | Unlimited | ||||
|
Nodes per Gateway & Readers
per Control Unit |
One primary CU and four auxiliary
CU per IP. Each CU controls 2 readers. |
One Gateway and six nodes per
IP. Each controls 16 openings ( 112 openings per IP) |
BLUEnet - same as RFnet
SVN+Flex - 2 flex locks per node and a total of 10 flex locks per |
gateway