Installation Instructions
Drill holes
- 1. Drill one ø 2-1/8" (54 mm) through hole as shown on the template.
- 2. Drill one 5/16" (8.1 mm) on outside face of door for use with anti-rotation studs.
Install Trim
- 1. Insert trim into the holes in door from outside of door.
-
2. Place 9-hole bracket plate into the hole on inside face of door.
- Make sure the 9-hole bracket plate is seated at a right angle. The orientation of the bracket plate must match the recessed back of the exit device. Bracket plate holes A and B must align with the trim mounting posts.
- 3. Insert the two (2) provided mounting screws through the 9-hole bracket plate and into the mounting posts of the trim, and tighten the mounting screws.
Install Exit Device
- 1. Install the exit device on inside face of door using the two (2) provided round head screws. For details on exit device installation, see exit device installation instructions.
- Make sure the trim spindle is inserted into the device cam on the back of the exit device.
- 3. Check the exit device and trim to be sure each is securely installed and adequately tightened for best operation.
Customer Service
1-877-671-7011 ww