FCBP MEL Kit For 3690 Exit Device Cut Sheet
Open the original PDF document
View PDF
MEL3000-1 S E R I E S
RETRO FIT KIT
(For CVR or RIM Devices)
MEL is available on First Choice Model 3690 CVR and 3790 RIM Devices
- Seemlessly Integrate your exit devices with building security systems.
- Unlock your exit devices remotely
- Coordinate exit device operation with auxillary devices such as automatic doors
UL Listed – ANSI Grade 1 (Reference UL File Sa12590)
These devices are equipped with quiet powerful motors suitable for high traffic conditions and capable of extended periods of activation.
POWER SUPPLIES
The MEL panic devices can be partnered with the PSMEL1500-1 or the PSMEL2000 power supplies.
This power supply is 115vAC and come equipped with terminal blocks for easy connection to input devices. The PSMEL2000 is capable of supplying power to 2 (two) doors while the ancillary devices such as key pads, card readers, and automatic door activation switches.
Complete Your Systems with Selection of Power Transfers
MEL3000-1
2-CONDUCTOR (Stranded Only)
| Wire Gauge | Maximum Distance | |
| 12 AWG | 720 FEET | |
| 14 AWG | 450 FEET | |
| 16 AWG | 280 FEET | |
| 18 AWG | 180 FEET | |
| 20 AWG | 110 FEET | |
| 22 AWG | 70 FEET | |
| POWER SUPPLY SELECTOR |
PSMEL
1500-1 |
PSMEL
2000 |
|---|---|---|
| Powers up to 1 (one) MEL Device | V | V |
| Powers up to 2 (two) MEL Devices | V | |
| Adjustable delay for exit device relocking | / | |
| Capable of triggering external relays | V | |
| Provide delayed triggering for automatic doors | V | |
| 24vDC auliallary power for keypad, card readers, motion detectors etc. | / | V |
| 12vDC auliallary power for keypad, card readers, motion detectors etc. | V | |
| Designed with logic protecting against accidental shorting of lock outputs | V | V |
| Built-in battery back-up available | V | |
| Fire Alarm Interface | V | V |
| Independent or sequential door control with output relays for ADA actuators | V | |
| Testing and agency approval UL=294/ulc-S319 | V | / |