| Condition | Parameters | |||
|---|---|---|---|---|
| Green LED | Red LED | Duration | Rate | |
| Valid pushbutton pressed | ON | OFF | 1/10 sec | Once |
| Keypad Timeout expired | OFF | ON | 1 sec | Once |
|
Valid access
code keyed |
ON | OFF | 1 sec | Once |
| Access granted | ON | OFF | 1/10 sec |
1 sec; till end of
unlockout time |
| Access granted (battery low condition) | ON | ON | 1/10 sec |
1 sec; till end of
unlockout time |
| Access denied | OFF | ON | 1 sec | Once |
| Valid programming entry | ON | OFF | 1 sec | Once |
|
Invalid programming
entry (including duplicate access code) |
OFF | ON | 1 sec | Once |
|
Tamper shutdown
beginning |
OFF | ON | 2 sec | Once |
| Tamper shutdown state | OFF | ON | 1 sec | 10 sec; till end of tamper shutdown time |
|
Tamper shutdown
ending |
ON | OFF | 2 sec | Once |
| Communication starting | ON | OFF | 1 sec | Once |
| Communication ending | ON | OFF | 1 sec | Once |
| Communication aborted | OFF | ON | 1 sec | Once |
| Communication in progress |
ON
(Alternate) |
ON
(Alternate) |
1/10 sec |
1 sec; till end of
communication with M-unit PDA |
| Lock model, feedback |
On
(Alternate) |
On
(Alternate) |
1/2 sec. | Once |
|
Deadbolt/Thumbturn
Privacy Activated |
OFF | On | 1 sec. | Once |
|
Deadbolt/Thumbturn
Privacy De-activated |
On | OFF | 1 sec. | Once |
| Hard reset sequence in progress |
On
(Alternate) |
On
(Alternate) |
1/2 sec. |
1/2 sec.; till end
of reset sequence |
|
End of successful
hard reset |
On | OFF | 2 sec. | Once |
|
End of unsuccessful
hard reset |
OFF | On | 2 sec. | Once |
E-PLEX ° Quick Reference Guide
To begin, put lock in programming mode by pressing: #Master Code# Summary of Pushbutton Programming Commands
| Name | Command | Description of Command |
|---|---|---|
| Configure |
000 #
MMMMMMM# MMMMMMM# |
'Modify Master User Access Code (lock's activation)' (Always 8 digits) |
| 001# | 'Date setup' (MM = 01 to 12; DD = 01 to 31; | |
|
MMDDYY#
MMDDYY# |
YY = 00 to 99) | |
| 002 # | 'Time setup' (HH = 00 to 23; MM = 00 to 59) | |
|
HHMM#
HHMM# |
||
| 003 # | 'Lock ID setup' (NNNN = 0000 to 9999) | |
| NNNN# | ||
| 004# | 'Unlock time setup' (TT = 02 to 20 seconds) | |
| TT# | ||
| 005 # |
'Passage Mode Timeout setup' (TT = 01 to 24
hours - duration time in hours; 00 = no time lim |
|
| TT# | nodra duration time in nodra, oo – no time iiinit | |
| 006# | 'Tamper time setup' (TT = 00 to 90 seconds) | |
| TT# | ||
| 007 # | 'Tamper wrong try setup' (TT = 03 to 09) | |
| TT# | ||
| 008# | 'Buzzer volume control' (VV = 00 to 03; 00 = off | |
| VV# | 01 = Low; 02 = Normal; 03 = High) | |
| 009 # | 'Modify access length' (LL = 04 to 08 digits) | |
| LL# | ||
Kaba Access & Data Systems Americas 2941 Indiana Avenue Winston-Salem, NC 27105 USA Tel: (800) 849-8324 (336) 725-1331 Fax: (800) 346-9640 (336) 725-3269
Summary of Pushbutton Programming Commands
| Name | Command | Description of Command |
|---|---|---|
| Configure | 099 # |
'Reset to factory default values', except access
code length. (Master, manager, and access user are retained if already programmed.) |
|
Add/Modify
Users |
100 #
NNN # UUUU {UUUU}# UUUU {UUUU}# |
'Add/Modify User Access Code' NNN = specific
User ID location (001 to 299) (Combination length can be 4 to 8 digits, depending on access length LL setting) |
|
101 #
NNN # UUUU {UUUU}# UUUU {UUUU}# |
'Add/Modify Manager Access Code' NNN =
specific User ID location (001 to 299) (Combination length can be 4 to 8 digits, depending on access length LL setting) |
|
|
102 #
NNN # UUUU {UUUU}# UUUU {UUUU}# HH# |
'Add/Modify Service User Access Code' NNN =
specific User ID location (001 to 299) (HH = 01 to 24 hours - duration time in hours; 00 = one time entry; Combination length can be 4 to 8 digits, depending on access length LL setting) |
|
|
103 #
UUUU {UUUU}# UUUU {UUUU}# |
'Modify M-Unit User Code' (Combination length
can be 4 to 8 digits, depending on access length LL setting) |
|
|
Delete
Users |
200 #
NNN# |
'Delete User Access Code' |
| 201 # | 'Delete Manager Access Code' | |
| NNN# | ||
|
202 #
NNN# |
'Delete Service User Access Code' | |
| 299 # |
'Delete all User Access Codes' (except Master,
Manager and M-Unit User) |
|
Summary of Pushbutton Programming Commands
| Name | Command | Description of Command |
|---|---|---|
|
Activate
Users |
300 # | 'Activate User Access Code' |
| NNN# | NNN = specific User ID location (001 to 299) | |
| 301 # | 'Activate Manager Access Code' | |
| NNN# | NNN = specific User ID location (001 to 299) | |
| 302 # | 'Activate Service User Access Code' | |
| NNN# | NNN = specific User ID location (001 to 299) | |
| 303 # | 'Activate M-Unit User Code' | |
| 398 # |
'Activate all User Codes' (except Master, Manager
and M-Unit User) |
|
|
399 #
P# |
'Activate / De-Activate Passage Mode' (P = 0
or 1; 0 = disable Passage Mode; 1 = enable Passage Mode) |
|
|
De-Activate
Users |
400 # | 'De-Activate User Access Code' |
| NNN# | NNN = specific User ID location (001 to 299) | |
| 401 # | 'De-Activate Manager Access Code' | |
| NNN# | NNN = specific User ID location (001 to 299) | |
| 402 # | 'De-Activate Service User Access Code' | |
| NNN# | NNN = specific User ID location (001 to 299) | |
| 403 # | 'De-Activate M-Unit User Code' | |
| 498 # |
'De-Activate all User Codes' (except Master,
Manager, and M-Unit User) |
|
| 499 # |
'Activate / De-Activate Lockout Mode' (Master User
doesn't affect by Lockout Mode) (L = 0 or 1; 0 = |
|
| L# | disable Lockout Mode; 1 = enable Lockout Mode) | |
| Diagnostic | 500 # | 'Manual diagnostic' |
| 1234567890*# | ||
|
Communication
Startup |
900 # | 'Communications startup' |