EPlex 5000 Series Quick Reference Guide

Open the original PDF document

View PDF

Visual Feedback Message Definitions

Condition Parameters
Green LED Red LED Duration Rate
Valid pushbutton pressed ON OFF 1/10 sec Once
Keypad Timeout expired OFF ON 1 sec Once
Valid access
code keyed
ON OFF 1 sec Once
Access granted ON OFF 1/10 sec 1 sec; till end of
unlockout time
Access granted (battery low condition) ON ON 1/10 sec 1 sec; till end of
unlockout time
Access denied OFF ON 1 sec Once
Valid programming entry ON OFF 1 sec Once
Invalid programming
entry (including
duplicate access code)
OFF ON 1 sec Once
Tamper shutdown
beginning
OFF ON 2 sec Once
Tamper shutdown state OFF ON 1 sec 10 sec; till end of tamper shutdown time
Tamper shutdown
ending
ON OFF 2 sec Once
Communication starting ON OFF 1 sec Once
Communication ending ON OFF 1 sec Once
Communication aborted OFF ON 1 sec Once
Communication in progress ON
(Alternate)
ON
(Alternate)
1/10 sec 1 sec; till end of
communication with
M-unit PDA
Lock model, feedback On
(Alternate)
On
(Alternate)
1/2 sec. Once
Deadbolt/Thumbturn
Privacy Activated
OFF On 1 sec. Once
Deadbolt/Thumbturn
Privacy De-activated
On OFF 1 sec. Once
Hard reset sequence in progress On
(Alternate)
On
(Alternate)
1/2 sec. 1/2 sec.; till end
of reset sequence
End of successful
hard reset
On OFF 2 sec. Once
End of unsuccessful
hard reset
OFF On 2 sec. Once

E-PLEX ° Quick Reference Guide

To begin, put lock in programming mode by pressing: #Master Code# Summary of Pushbutton Programming Commands

Name Command Description of Command
Configure 000 #
MMMMMMM#
MMMMMMM#
'Modify Master User Access Code (lock's activation)' (Always 8 digits)
001# 'Date setup' (MM = 01 to 12; DD = 01 to 31;
MMDDYY#
MMDDYY#
YY = 00 to 99)
002 # 'Time setup' (HH = 00 to 23; MM = 00 to 59)
HHMM#
HHMM#
003 # 'Lock ID setup' (NNNN = 0000 to 9999)
NNNN#
004# 'Unlock time setup' (TT = 02 to 20 seconds)
TT#
005 # 'Passage Mode Timeout setup' (TT = 01 to 24
hours - duration time in hours; 00 = no time lim
TT# nodra duration time in nodra, oo – no time iiinit
006# 'Tamper time setup' (TT = 00 to 90 seconds)
TT#
007 # 'Tamper wrong try setup' (TT = 03 to 09)
TT#
008# 'Buzzer volume control' (VV = 00 to 03; 00 = off
VV# 01 = Low; 02 = Normal; 03 = High)
009 # 'Modify access length' (LL = 04 to 08 digits)
LL#

Kaba Access & Data Systems Americas 2941 Indiana Avenue Winston-Salem, NC 27105 USA Tel: (800) 849-8324 (336) 725-1331 Fax: (800) 346-9640 (336) 725-3269

Summary of Pushbutton Programming Commands

Name Command Description of Command
Configure 099 # 'Reset to factory default values', except access
code length. (Master, manager, and access user
are retained if already programmed.)
Add/Modify
Users
100 #
NNN #
UUUU {UUUU}#
UUUU {UUUU}#
'Add/Modify User Access Code' NNN = specific
User ID location (001 to 299) (Combination length
can be 4 to 8 digits, depending on access length
LL setting)
101 #
NNN #
UUUU {UUUU}#
UUUU {UUUU}#
'Add/Modify Manager Access Code' NNN =
specific User ID location (001 to 299)
(Combination length can be 4 to 8 digits,
depending on access length LL setting)
102 #
NNN #
UUUU {UUUU}#
UUUU {UUUU}#
HH#
'Add/Modify Service User Access Code' NNN =
specific User ID location (001 to 299) (HH = 01
to 24 hours - duration time in hours; 00 = one
time entry; Combination length can be 4 to 8
digits, depending on access length LL setting)
103 #
UUUU {UUUU}#
UUUU {UUUU}#
'Modify M-Unit User Code' (Combination length
can be 4 to 8 digits, depending on access length
LL setting)
Delete
Users
200 #
NNN#
'Delete User Access Code'
201 # 'Delete Manager Access Code'
NNN#
202 #
NNN#
'Delete Service User Access Code'
299 # 'Delete all User Access Codes' (except Master,
Manager and M-Unit User)

Summary of Pushbutton Programming Commands

Name Command Description of Command
Activate
Users
300 # 'Activate User Access Code'
NNN# NNN = specific User ID location (001 to 299)
301 # 'Activate Manager Access Code'
NNN# NNN = specific User ID location (001 to 299)
302 # 'Activate Service User Access Code'
NNN# NNN = specific User ID location (001 to 299)
303 # 'Activate M-Unit User Code'
398 # 'Activate all User Codes' (except Master, Manager
and M-Unit User)
399 #
P#
'Activate / De-Activate Passage Mode' (P = 0
or 1; 0 = disable Passage Mode; 1 = enable
Passage Mode)
De-Activate
Users
400 # 'De-Activate User Access Code'
NNN# NNN = specific User ID location (001 to 299)
401 # 'De-Activate Manager Access Code'
NNN# NNN = specific User ID location (001 to 299)
402 # 'De-Activate Service User Access Code'
NNN# NNN = specific User ID location (001 to 299)
403 # 'De-Activate M-Unit User Code'
498 # 'De-Activate all User Codes' (except Master,
Manager, and M-Unit User)
499 # 'Activate / De-Activate Lockout Mode' (Master User
doesn't affect by Lockout Mode) (L = 0 or 1; 0 =
L# disable Lockout Mode; 1 = enable Lockout Mode)
Diagnostic 500 # 'Manual diagnostic'
1234567890*#
Communication
Startup
900 # 'Communications startup'