Corbin Russwin DC3000 Series Door Closer Catalog_45045

Open the original PDF document

View PDF

DC3000 Series Door Closers

Product Catalog

Applications

DC3000 Series

Table of Contents

Applications
2
Features 3 & 4
Mountings5 & 6
Door Closer Arms
7 & 8
Mounting Brackets

9
Brackets and Covers
10
Size, Weight, Handing

11
How to Order

12
Quick Codes
13
Helpful Terms
14
How to Specify
15

www.corbinrusswin.com

DC3000 Series

Applications

The mid-priced, cost-effective choice for high-traffic situations. The DC3000 Series Door Closers fulfill security and life safety requirements by ensuring reliable latching for access control and fire code compliance, along with ease of operation and precise adjustability for barrier-free code compliance. Ideal for virtually all door openings and draft conditions in both new construction and renovations, including:

  • Schools and universities
  • Health care
  • Government
  • Commercial and industrial
  • Office and retail
  • Transportation and utilities
  • Hotels and conference centers
  • Religious

Advantages

  • Meets or exceeds ANSI/BHMA A156.4 Grade 1 requirements
  • Compliance with building and barrier-free codes

  • One-piece seamless steel spring tube seals in hydraulic fluid
  • Tapered valves allow precise adjustment
  • Cast iron body
  • Quik-Install™ mounting bracket speeds installation, reducing cost and errors
  • 15-year limited warranty
  • UL10C positive pressure for up to 3-hours
  • Powder painted arms and retrofit plates

Overview

DC3000 Series

Overview of Features

Features DC3200 Closers
Spring power Multi-sized; Adjustable 1-6
Latching speed valve Standard
Closing speed valve Standard
Backcheck intensity valve Standard
Delayed action valve Optional
Parallel arm mounting Optional
Top jamb mounting Optional
Hold open Optional
Sex nuts and bolts (SNBs) Optional
Corrosion protection Optional
Full cover Standard
15-year warranty Standard
Heavy-duty regular arm Optional
Heavy-duty parallel arm Optional
Backstop arm Optional
Finishes
Old Designation Description Specify
USP Primed 600
N/A Dark Oxidized Satin Bronze - equivalent 613E
SBL Silver Aluminum 689
DBL Dark Bronze 690
LBL Light Bronze 691
FBL Black 693
GBL Satin Brass 696
N/A Black Suede Powder Coat BSP
N/A White Suede Powder Coat WSP

Features

DC3000 Series

Features

Spring Power

Multi-sized; fully adjustable 1 through 6.

Handina

Non-handed.

Body

Cast iron case with seamless cold-headed steel spring tube.

Arm

Standard: forged steel. Optional arms, pages 7 and 8.

Spindle

Cold-headed heat-treated steel.

Pistor

1-3/8" diameter; Precision machined, heat-treated steel.

Springs

Chrome silicon wire.

Valves

Latching speed, closing speed and backcheck intensity valves standard. Delayed action valve optional (preset for 20 seconds; between 90° and 70° for all mountings.) To order, specify M71.

Seals

"O"rings.

Fluid

Standard high lubricity extreme temperature hydraulic fluid.

Degree of Opening

Up to full 180° opening standard for regular, top jamb and parallel arm mountings, conditions permitting.

Power Adjustment Arm Bracket

15% adjustment standard.

Cover

Non-metallic full cover.

Mountings

Standard: regular arm and top jamb. Parallel arm or tri-style packaging - specify DC3210 Optional mountings; see page 6.

Mounting Bracket

Quik-Install™ mounting bracket standard.

Fasteners

Standard: self-drilling screws. Optional: sex nuts and bolts (SNBs); Specify

Corrosion Protection

Painted protective coating on all metal surfaces for use in corrosive environments. Specify M75.

Warrantv

15-year limited warranty. Refer to Corbin Russwin price book for details.

Certification/Compliance

Barrier-Free Code Compliance

The DC3000 Series Door Closers listed below conform to

the 5 lbf. maximum door opening force requirement for non-fire-rated interior hinged doors, according to:

Americans with Disabilities Act (ADA)

Complies with the Accessibility Guidelines for Buildings and Facilities, Section 4.13.11.

ANSI/BHMA Certified

A156.4, Grade 1. A117.1.

UL10C positive pressure up to 3 hours UL-cUL

Listed for fire and cycle requirements.

CAUTION: Door Closers for Low Opening Force Applications:

Door closers installed in openings required to meet the requirements of the Americans With Disabilities Act or ANSI/BHMA Standard A117.1, when adjusted to meet those requirements, may not provide adequate closing power to dependably close and latch the door based on opening or site conditions.

Mountings

DC3000 Series

DC3200 Regular Arm Mounting

  • Most common mounting, providing the greatest closing efficiency
  • Closer is mounted on the pull side, with the arm perpendicular to the face of the door
  • Arm bracket is attached to the door frame

DC3210 Parallel Arm Mounting

  • Allows inside application of closer on out-swinging doors
  • Closer is mounted on the push side, with the arm parallel to the face of the door
  • Arm does not project from the opening

DC3220 Top Jamb Mounting

  • Accommodates reveals up to 3-1/4" (83mm)
  • Closer is mounted on the push side, with the arm perpendicular to the face of the door
  • Arm bracket is mounted on the door
  • Minimum 1-3/4" (44mm) top jamb required

Contact factory if door weight exceeds 250 lbs.

Mountings

DC3000 Series

Regular Arm Mounting with Mortise Arm Bracket

Used on inadequately reinforced frames, such as those with bull nose trims.

Parallel Arm with Offset Angle Bracket Mounting

Allows parallel arm mounting when used with an overhead door holder.

Parallel Arm Mounting with Flush Transom Bracket

Allows parallel arm mounting on flush transom applications.

Top Jamb Flush Transom Mounting

Closer is top jamb mounted on the push side; arm is attached to the door.

Narrow Frame Mounting

For use when the frame is too narrow for a normal top jamb or top jamb track mounting. (Shown with 188F65 drop plate)

Top Jamb Deep Reveal Mounting

For reveals greater than 3-1/4" (83mm), up to 7-1/4" (184mm).

Door Closer Arms

DC3000 Series

Regular Arm

  • Used with regular arm mounting (pull side) and top jamb mounting (push side)
  • Non-Hold Open arm standard on the DC3200
  • Hold Open arm optional, specify closer x A1*

Heavy-Duty Regular Arm

  • Recommended for high-use, high-abuse environments
  • Tamper-resistant, solid forged steel riveted arm
  • Mounted on pull side
  • Optional on DC3200 closer, specify closer x A10

688F95 x 188F41 (Non-Hold Open)

Parallel Arm

  • Mounted on push side
  • Non-Hold Open arm combines regular arm with parallel arm mounting bracket
  • Hold Open arm combines regular hold open arm with parallel arm mounting bracket
  • Non-Hold Open arm standard on the DC3210
  • Hold Open arm optional, specify closer x A1*

*Not allowed by code on fire doors.

Door Closer Arms

DC3000 Series

Top Jamb

  • Used with top jamb mounting (push side); for reveals up to 3-3/4" (95 mm)
  • Non-Hold Open arm standard on the DC3220
  • Hold Open arm optional, specify closer x A1*

Heavy-Duty Parallel Arm

  • Recommended for high-use, high-abuse environments
  • Tamper-resistant, solid forged steel riveted arm
  • Mounted on push side
  • Optional on DC3210 closers
  • Non-hold open arm, specify closer x A3
  • Hold open arm, specify closer x A2 *. Hold-open range 85° to 110°

689F03 (Non-Hold Open)

Heavy-Duty Reversible Backstop Parallel Arm

  • Recommended for high-use, high-abuse environments
  • Tamper-resistant, solid forged steel riveted arm (mounted on push side)
  • Field-reversible steel lug restricts degree of opening to protect door, wall and hardware
  • Requires both backcheck valves on closer
  • Shipped standard as left hand. Handing can be reversed in the field
  • Optional on DC3210 closers
  • Non-hold open arm, specify closer x A4 . Door stop range 85° to 110°
  • Hold open arm, specify closer x A5 *. Door stop/hold open range 85° to 110°

*Not allowed by code on fire doors.

Mounting Brackets

DC3000 Series

188F03

Quik-Install™ Mounting Bracket

  • Standard on all closers
  • Reduces installation time
  • Ensures correct mounting
  • Bracket is first mounted to door or frame, then closer is attached
  • Bracket size: 1-3/4" (44mm) (vertical) x 6" (152mm) (horizontal)
  • Hole spacing: 1" (25mm) (vertical) x 4-5/16" (110mm) (horizontal)

244F17

Mortise Arm Bracket for Regular Arm Mounting

  • For regular arm mounting where frame requires reinforcement, i.e., on frames with bull nose trim
  • Specify closer x M84

188F41

Parallel Arm Non-Hold Open Bracket

  • Converts regular arm to parallel arm closer
  • Standard with parallel arm mounting
  • Packed with five screws and 691F78 spacer

509F49

Parallel Arm Hold Open Bracket

  • Converts regular arm hold open to parallel arm hold open closer
  • Standard with parallel arm hold open mounting

188F62

Parallel Arm Offset Bracket

  • Required when parallel arm is used in conjunction with an overhead door holder
  • Specify closer x M83

188F63

Parallel Arm Flush Transom Bracket

  • Required when parallel arm mounting is used on a flush transom application
  • Specify closer x M82

Specify finish when ordering parts.

Brackets and Covers

DC3000 Series

Drop Plate (Option M80)

Permits parallel arm or top jamb mounting on door when top rail is too narrow to install closer in the regular manner. Minimum 2" top rail required. Optional on DC3000 series closers; see Quick Codes, page 13. To order separately, specify drop plate number x Finish

Drop Plates
Closer Series Full Cover
DC3210 597F58
DC3220 188F65

Power Adjustment Arm Bracket

Standard on all closers without hold open. In regular arm or top jamb mounting, bracket may be reversed to increase closing power 15%.

447F14

Angle Support Bracket and Spacer

  • Available separately for mounting of A2, A3, A4 and A5 heavy-duty arms on narrow frame or soffit conditions
  • Specify closer x M85

597F78

Full Cover

  • Standard on all DC3000 series door closers
  • Completely covers closer body
  • Non-handed
  • Dimensions: 11-5/8" (295mm) x 3" (76mm) x 2-3/4" (70mm) deep

Size and Handing

DC3000 Series

Factors in Determining Closer Size

1 - Weight and Height of Door

Doors vary in weight from light hollow-core wood doors to heavy metal doors. Door sizes listed in the chart are based on doors of standard weight and height. Extra-light or extra-heavy weight or unusual height must be compensated for. Contact factory if door weight exceeds 250 lbs.

2 - Draft and Wind Conditions

Draft and wind conditions are perhaps the most important factors to consider in determining the closer size required. Sizes listed in the chart apply to normal conditions. Stairwells, air conditioning, building construction, and door location can cause strong draft and wind conditions; these may necessitate adjusting spring power to a larger size or using a closer one size larger.

3 - Code Compliance

A multi-sized, fully adjustable closer such as the DC3200 closer provides the greatest flexibility in balancing barrier-free access, security and life safety codes. However, when a manual closer is installed and adjusted to comply with ADA or any other reduced opening force requirements, it may no longer have sufficient power to close and latch the door reliably.

Recommended Door Closer Sizes
Size Of Door Recommended
Mounting Interior Exterior
In-swinging
Exterior,
Out-swinging
Closer Size
Adjusted
2'4" _ - 1
3'0" - - 2
Regular or Top 3'6' 2'6" 3'0" 3
Jamb 4'0" 3'0" 3'6" 4
4'6" 3'6" 4'0" 5
5'0" 4'0" 4'6" 6
2'4" _ _ 1
2'6" - - 2
Parallel Arm 3'0' _ 2'6" 3
Parallel Arm 3'6" - 3'0" 4
4'0" _ 3'6" 5
4'6" - 4'0" 6

Handing

Refers to the direction a door swings; always determined from the outside of the door.

Regular Mounting

Door: left hand Closer: left hand pull side

Door: right hand Closer: right hand pull side

Parallel Arm Mounting

Door: left hand reverse bevel Closer: right hand push side

Door: right hand reverse bevel Closer: left hand push side

Top Jamb Mounting

Door: left hand reverse bevel Closer: right hand push side

Door: right hand reverse bevel Closer: left hand push side

How to Order

DC3000 Series

ANSI/BHMA A156.4 Certified Closer Cross Reference

ANSI/BHMA
Number
Function Series PT 4A
15% Power
Adjustment
PT 4B
35% Power
Adjustment
PT 4C
50% Power
Adjustment
PT 4D
Adjustable
Backcheck
PT 4F
Delayed
Action PT
4G
Dead
Stop PT
4H
Fully
Adjustable
CO2011
(PT1)
Hinge Side
Mounting
DC3200 S S S S O N/A S
CO2051
(PT1)
Hinge Side
Mounting
Holder Arm
DC3200-A1 S S S S O N/A S
CO2021
(PT1)
Parallel Arm
Mounting
DC3210 S S S S O O S
CO2061
(PT1)
Parallel Arm
Mounting
Holder Arm
DC3210-A1 S S S S O O S
CO2041
(PT1)
Top Jamb
Mounting
DC3220 S S S S O N/A S
CO2081
(PT1)
Top Jamb
Mounting
Holder Arm
DC3220-A1 S S S S O N/A S
CO2191
(PT1)
Drop Plate
for Frames or
Narrow Top Rail
Doors
DC3220 w/
188F65
S S S S O N/A S
CO2201
(PT1)
Drop Plate for
Parallel Arm
Mounting on
Narrow Top Rail
Doors
DC3210 w/
188F65 or
597F58
S S S S O O S

ANSI Performance Requirements: (PT 1)- 2,000,000 cycles N/A = not available S = standard O = option available

Ordering Examples

Stock Order
Quantity Series Finish
50 DC3200 689
Contract Order
Quantity Series Arm Finish Hand Door
Thickness
Misc.
Options
150 DC3220 A1 690 RH D138 M54

NOTE:

  • Before installing a door closer, verify the accessibility, fire, and life-safety requirements that are in effect. This includes the mounting height and projection into the clear opening. Check the adopted state and local building codes and consult the Authority Having Jurisdiction (AHJ).
  • To maintain the warranty and ensure proper operation of the product, follow the installation instructions & templates and install on the inside of the building.
  • Consult NFPA 80 for the hinge requirements on a fire door.
  • Failure to use fasteners supplied with closer may void factory warranty.
  • Optional fasteners are available for a variety of applications. Consult the door and frame manufacturer to ensure the proper fasteners are used to maintain certifications.
  • Sizing charts are based on 1-3/4" x 7' standard weight doors swinging to 110°. Other application conditions (e.g. larger door heights or weight) may require larger size closer. Adjusting the spring power to meet the low opening force requirements of the Americans With Disabilities Act or ANSI/ BHMA Standard A117.1, may not provide adequate closing power to dependably close and latch the door in some conditions (i.e. air movement from wind gusts or building stack pressure).

Quick Codes

DC3000 Series

Series/Mounting/Size
Description Mounting Specify
DC3200 Closers
Multi-sized; full
adjustability from
size 1-6
Regular Arm DC3200
Parallel Arm DC3210
Top Jamb DC3220
Arm
Description Specify
Regular non-hold open (standard)
Hold open A1*
Heavy-duty parallel with hold open A2*
Heavy-duty parallel non-hold open A3
Heavy-duty backstop non-hold open A4
Heavy-duty backstop with hold open A5*
Heavy-duty regular non-hold open A10

* Hold Open arms cannot be used on fire doors.

Handing
Hand Specify
Right Hand/Left Hand Reverse RH
Left Hand/Right Hand Reverse LH
Finish
Description Specify
USP Primed for Painting 600
N/A Dark Oxidized Satin Bronze -
equivalent
613E
SBL Silver Aluminum Painted 689
DBL Dark Bronze Painted 690
LBL Light Bronze Painted 691
FBL Black Painted 693
GBL Satin Brass Painted 696
BSP Black Suede Powder Coat BSP
WSP White Suede Powder Coat WSP
Door Thickness
Door Thickness Specify
1-3/4" (44mm) (standard)
2" (51mm) D200
2-1/4" (57mm) D214
Miscellaneous Options
Description Specify
Sex nuts and bolts (SNBs)
(1-3/4" minimum thickness)
M54
Delayed action M71
Full cover (standard)
Corrosion protection M75
Heavy-duty parallel arm flush transom
bracket (499F30) used with A2, A3, A4,
A5 arms
M79
Parallel arm flush transom bracket (parallel
or A1)
M82
Parallel arm offset bracket M83
Mortise arm bracket (for regular arm
mounting)
M84
Angle support bracket M85
Extreme temperature fluid (standard)
Drop Plates - order by number (formerly M80)
Closer Series Drop Plate
DC3210 (parallel) 597F58
DC3220 (top jamb) 188F65
Paint (cans)
Description Specify
Silver Aluminum 597F94
Dark Bronze 597F95
Light Bronze 597F96
Satin Brass 597F97

Helpful Terms

DC3000 Series

Arm

The linkage of a closer that connects the body to the door or frame.

Backcheck

Slows a door during the opening cycle, by providing cushioned resistance to a forceful opening. Designed to protect people and objects behind the door and to prevent damage to the closer, hardware, and wall. Intensity can be increased or decreased. Not intended to act as a stop.

Closing Speed

The speed at which a door swings from the open position to within a few degrees of latching. See Latching Speed.

Corrosion Protection

Additional painted covering on all external parts to deter oxidation and corrosion.

Door Stop

A device to stop the swing of a door.

Hold Open

Maintains door at a particular degree of opening. A mechanical hold open may not be used on labeled fire doors, which must be self-closing.

Latching Speed

The speed of the door during the last few degrees of closing. Allows latching and prevents slamming.

Mounting

The method by which a closer is attached to the door and frame.

Multi-Sized Closer

A closer whose spring tube design allows full adjustment of the spring power size from 1 through 6.

Quik-Install™ Mounting Bracket

Unique bracket that simplifies installation and minimizes installer fatigue.

Sex Nuts and Bolts (SNBs)

Thru-bolts required for all non-steel-reinforced fire doors, and recommended for non-reinforced wood and mineral core doors.

Spring Power

A measurement of closing force, or the ability to overcome draft, air pressure, weight or other resistance to door closing.

Star Punch

An eight-sided socket hole in the closer arm, permitting spindle pre-loading. Provides full functioning of backcheck and delayed action valves, and additional closing force, on parallel arm mountings.

Universal Mounting

The ability of a closer to accommodate either hand of door for regular, top jamb or parallel arm mounting.

How to Specify

DC3000 Series

Suggested Specifications

All door closers shall be DC3000 Series Door Closers as manufactured by Corbin Russwin Architectural Hardware.

Closers shall be of rack and pinion construction with a triple heat treated cold-formed steel spindle and a steel piston, heat treated and precision machined. Cases shall be of cast iron with a one-piece seamless forged spring tube. A two-piece or seamed spring tube shall not be acceptable. Springs shall be double heat treated and tempered. Closers shall have a heavy-duty, forged steel main arm.

Optional arms shall include parallel, hold open, heavy-duty, heavy-duty hold open, heavy-duty reversible backstop and heavy-duty reversible backstop with hold open.

Closers shall be multi-sized with adjustable spring power to accommodate sizes 1 through 6 in one closer body, such as the Corbin Russwin DC3200 closer. Closing shall be controlled by two valves - one to control closing speed and one to control latching speed. Valves shall be concealed against unauthorized adjustment and shall be non-critical with "O" rings.

Closers shall be available with an adjustable backcheck intensity valve. Delayed action shall be available and accomplished with a separate valve. Valves shall be accessible without removing the closer from the door.

Closers shall be surface applied with rectangular cover, and shall be devoid of manufacturer's trademarks.

Closers shall not project over 2-3/4", and shall be capable of mounting on a 1-3/4" top rail (or top jamb for inverted mounting). Full cover shall be standard. Non-hold open closers shall be regularly furnished with a power adjustment arm bracket capable of providing a 15% power adjustment. A Quik-Install™ mounting bracket to attach the closer shall be regularly furnished. High lubricity hydraulic fluid shall be furnished. Closers mounted top jamb and parallel arm shall allow for full 180° door opening.

Closers shall be listed by Underwriters' Laboratories for closers with non-hold open arms.

Certification: ANSI/BHMA A156.4, Grade 1 UL10C positive pressure up to 3 hours UL-cUL ICC/ANSI A117.1

Closers shall carry a 15-year limited warranty.

The ASSA ABLOY Group is the global leader in access solutions. Every day, we help billions of people experience a more open world.

ASSA ABLOY Opening Solutions leads the development within door openings and products for access solutions in homes, businesses and institutions. Our offering includes doors, frames, door and window hardware, mechanical and smart locks, access control and service.

For additional information, contact your ASSA ABLOY Door Security Solutions sales consultant or visit www.corbinrusswin.com.

In U.S.

Corbin Russwin Architectural Hardware 225 Episcopal Road Berlin, CT 06037 Phone: 800-543-3658 Fax: 800-447-6714 www.corbinrusswin.com

In Canada

ASSA ABLOY Door Security Solutions Canada 160 Four Valley Drive Vaughan, Ontario Canada L4K 4T9 Phone: 800-461-3007 Fax: 800-461-8989 www.assaabloydss.ca