Z-Wave Association and Configuration Parameters
Touchscreen Deadbolt with Alarm | Model BE469 Connected Touchscreen | Model BE468
This page describes the supported association groups and configuration parameters. This information is available for advanced users who wish to manually configure these parameters.
Association Group Information
The Touchscreen Deadbolt with Alarm supports one association group which may contain up to two nodes. This group is group number one.
Configuration Parameters
The table below summarizes the supported configuration parameters. Please reference your controller or gateway documentation for directions to set these parameters.
| Param # |
Descripti
on |
Read
/ Write |
Size |
Config
Value |
Value |
Value Descripti
on |
Associati
on |
|---|---|---|---|---|---|---|---|
|
0x00 –
0x02 |
Reserved | N/A | N/A | N/A | N/A | N/A | N/A |
| 0x03 | Beeper | R/W | 1 | 1 | 0x00 | Disable Beeper | Yes |
| 0xFF | Enable Beeper | ||||||
| 0x04 | Vacation Mode | R/W | 1 | 1 | 0x00 | Disable Vacation Mode | Yes |
| 0xFF | Enable Vacation Mode | ||||||
| 0x05 | Lock & Leave | R/W | 1 | 1 | 0x00 | Disable Lock & Leave | Yes |
| 0xFF | Enable Lock & Leave | ||||||
| 0x06 |
User Slot Bit Field
(Occupied slots) |
R | 4 | 1 | 0x00 – 0xFF |
User Slots 8 – 1 (MSB –
LSB) |
No |
| 8,7,6,5,4,3,2,1 | |||||||
| 2 | 0x00 – 0xFF |
User Slots 16 – 9 (MSB –
LSB) |
|||||
| 16, 15, 14, 13, 12, 11, 10, 9 | |||||||
| 3 | 0x00 – 0xFF |
User Slots 24 – 17 (MSB
– LSB) |
|||||
|
24, 23, 22, 21, 20, 19, 18,
17 |
|||||||
| 4 | 0x00 – 0xFF |
User Slots 30 – 25 (MSB
– LSB) |
|||||
| X, X, 30, 29, 28, 27, 26, 25 | |||||||
| 0x07 |
Lock Specific Alarm Mode
BE469 Only |
R/W | 1 | 1 | 0x00 | Alarm Off | Yes |
| 0x01 | Alert | ||||||
| 0x02 | Tamper | ||||||
| 0x03 | Forced Entry | ||||||
| 0x04– 0xFF | Reserved | ||||||
| 0x08 | Lock Specific Alarm Alert | R/W | 1 | 1 | 0x00 | Not supported | Yes |
| Sensitivity | 0x01 | Most Sensitive | |||||
| BE469 Only | 0x02 | ||||||
| 0x03 | Medium Sensitivity | ||||||
| 0x04 | |||||||
| 0x05 | Least Sensitive | ||||||
| 0x06 – 0xFF | Reserved | ||||||
| 0x09 | Lock Specific Alarm Tamper | R/W | 1 | 1 | 0x00 | Not supported | Yes |
|
Sensitivity
BE469 Only |
0x01 | Most Sensitive | |||||
| 0x02 | |||||||
| 0x03 | Medium Sensitivity | ||||||
| 0x04 | |||||||
| 0x05 | Least Sensitive | ||||||
| 0x06 – 0xFF | Reserved |
| Param # |
Descripti
on |
Read
/ Write |
Size |
Config
Value |
Value |
Value Descripti
on |
Associati
on |
|---|---|---|---|---|---|---|---|
| 0x0A | Lock Specific Alarm Kick | R/W | 1 | 1 | 0x00 | Not supported | Yes |
| Sensitivity | 0x01 | Most Sensitive | |||||
| BE469 Only | 0x02 | ||||||
| 0x03 | Medium Sensitivity | ||||||
| 0x04 | |||||||
| 0x05 | Least Sensitive | ||||||
| 0x06 – 0xFF | Reserved | ||||||
| 0x0B |
Lock Specific Alarm
Disable—Local Controls BE469 Only |
R/W | 1 | 1 | 0x00 |
Disable Local Control
(Disables local alarm on/off, mode change, sensitivity changes) |
No |
| 0xFF |
Enable Local Control
(Enables local alarm on/off, mode change, sensitivity changes) |
||||||
| 0x0C |
Get Electronic Transition
Count |
R | 4 | 1 – 4 |
0x00000000 –
0xFFFFFFFF |
Electronic Transition Count
– A transition is locked to unlocked or unlocked to locked |
No |
| 0x0D |
Get Mechanical Transition
Count |
R | 4 | 1 – 4 |
0x00000000 –
0xFFFFFFFF |
Mechanical Transition
Count – A transition is locked to unlocked or unlocked to locked |
No |
| 0x0E | Get Electronic Failed Count | R | 4 | 1 – 4 |
0x00000000 –
0xFFFFFFFF |
Electronic Failed count
– each failed attempt increments this count by one |
No |
| 0x0F | Auto Lock | R/W | 1 | 1 | 0x00 | Disable Auto Lock | Yes |
| 0xFF | Enable Auto Lock | ||||||
| 0x10 | User Code PIN Length | R/W | 1 | 1 | 0x04 – 0x08 |
User Code PIN length, a
value between 4 and 8 (default 4) |
Yes |
| 0x11 |
Get Electrical High Preload
Transition Count |
R | 4 | 1-4 |
0x00000000 –
0xFFFFFFFF |
Electronic High Preload
Transition Count – a subset of 0x0C above – transitions that occurred with high preload |
No |
| 0x12 | Get Bootloader Version | R | 1 | 1 | 0x00 – 0xFF |
Get the version of the
bootloader |
No |
2/1252/03
Parámetros de asociación y configuración del Z-Wave
Cerrojo de pantalla táctil con alarma | Modelo
Pantalla táctil conectada | Modelo BE468
Esta página describe los grupos de asociación compatibles y parámetros de configuración. Esta información está disponible para usuarios avanzados que desean configurar manualmente estos parámetros.
Información del grupo de asociación
El cerrojo de pantalla táctil con alarma admite un grupo de asociación que puede contener hasta dos nodos. Este grupo es el grupo número uno.
Parámetros de configuración
La tabla siguiente resume los parámetros de configuración admitidos. Consulte la documentación de su controlador o pasarela para obtener instrucciones para configurar estos parámetros.
|
N.º DE
PARÁMETRO |
DESCRIPCIÓN |
LECTURA/
ESCRITURA |
DIMENSIONES | VALOR DE CONFIGURACIÓN | VALOR | DESCRIPCIÓN DEL VALOR | ASOCIACIÓN |
|---|---|---|---|---|---|---|---|
| 0x00 - 0x02 | Reservado | N/D | N/D | N/D | N/D | N/D | N/D |
| 0x03 | Alerta sonora | L/E | 1 | 1 | 0x00 | Deshabilitar alerta sonora | Sí |
| | | 0xFF | Habilitar alerta sonora | |||||
| 0x04 | Modo de | L/E | 1 | 1 | 0x00 | Deshabilitar el modo de | Sí |
| vacaciones | vacaciones | ||||||
| 0xFF | Habilitar el modo de vacaciones | ||||||
| 0x05 | Bloquear y salir | L/E | 1 | 1 | 0x00 | Deshabilitar Bloquear y salir | Sí |
| 0xFF | Habilitar Bloquear y salir | ||||||
| 0x06 | Campo de | R | 4 | 1 | 0x00 - 0xFF | Ranuras del usuario 8 – 1 (MSB | |
| pasador de | - LSB) | ||||||
| ranura del | 8,7,6,5,4,3,2,1 | No | |||||
| usuario (ranuras | 2 | 0x00 - 0xFF | Ranuras del usuario 16 – 9 | ||||
| ocupadas) | (MSB – LSB) | ||||||
| ĺ | . , | 16, 15, 14, 13, 12, 11, 10, 9 | |||||
| 3 | 0x00 - 0xFF | Ranuras del usuario 24 – 17 | |||||
| (MSB – LSB) | |||||||
| 24, 23, 22, 21, 20, 19, 18, 17 | |||||||
| 4 | 0x00 – 0xFF | Ranuras del usuario 30 – 25 | |||||
| (MSB – LSB) | |||||||
| X, X, 30, 29, 28, 27, 26, 25 | |||||||
| 0x07 | Modo de alarma específico de la | L/E | L/E 1 | 1 | 0x00 | Alarma apagada | Sí |
| e la | 0x01 | Alerta | |||||
| cerradura | 0x02 | Manipulación | |||||
| Únicamente | 0x03 | Ingreso forzado | |||||
| BE469 | 0x04- 0xFF | Reservado | |||||
| 0x08 | Sensibilidad de la L/E alerta de alarma | oilidad de la L/E | 1 | 1 | 0x00 | No admitido | Sí |
| 0x01 | Más sensible | ||||||
| específica de la | 0x02 | ||||||
| cerradura | 0x03 | Sensibilidad intermedia | |||||
| Únicamente | 0x04 | ||||||
| BE469 | 0x05 | Menos sensible | |||||
| 0x06 - 0xFF | Reservado | ||||||
| 0x09 | Sensibilidad de | L/E | 1 | 1 | 0x00 | No admitido | Sí |
| | | manipulación de | 0x01 | Más sensible | ||||
| alarma específica | 0x02 | 1 | |||||
| de la cerradura | 0x03 | Sensibilidad intermedia | 1 | ||||
| Únicamente | 0x04 | | | |||||
| BE469 | 0x05 | Menos sensible | 1 | ||||
| DL-100 | 0x06 – 0xFF | Reservado | | |
|
N.° de
parámet ro |
Descripci
ón |
Lect
ura/ escritura |
Dimensiones |
Valor de
configuraci ón |
Valor |
Descripci
ón del valor |
Asociaci
ón |
|---|---|---|---|---|---|---|---|
| 0x0A | Sensibilidad de | L/E | 1 | 1 | 0x00 | No admitido | Sí |
| patada de alarma | 0x01 | Más sensible | |||||
| específica de la | 0x02 | ||||||
| cerradura | 0x03 | Sensibilidad intermedia | |||||
| Únicamente | 0x04 | ||||||
| BE469 | 0x05 | Menos sensible | |||||
| 0x06 – 0xFF | Reservado | ||||||
| 0x0B | Deshabilitar | L/E | 1 | 1 | 0x00 | Deshabilitar control local | No |
| alarma específica | (Deshabilita el encendido/ | ||||||
| de la cerradura: | apagado, cambio de modo y | ||||||
| controles locales | cambios de sensibilidad local de | ||||||
| Únicamente | la alarma) | ||||||
| BE469 | 0xFF | Habilitar control local (Habilita el | |||||
| encendido/apagado, cambio de | |||||||
| modo y cambios de sensibilidad | |||||||
| local de la alarma) | |||||||
| 0x0C |
Obtener recuento
de transición electrónica |
R | 4 | 1 – 4 | 0x00000000 – | Recuento de transición | No |
| 0xFFFFFFFF | electrónica: una transición pasa | ||||||
| de bloqueada a desbloqueada o | |||||||
| desbloqueada a bloqueada | |||||||
| 0x0D |
Obtener recuento
de transición mecánica |
R | 4 | 1 – 4 | 0x00000000 – | Recuento de transición | No |
| 0xFFFFFFFF | mecánica: una transición pasa | ||||||
| de bloqueada a desbloqueada o | |||||||
| desbloqueada a bloqueada | |||||||
| 0x0E | Obtener | R | 4 | 1 – 4 | 0x00000000 – | Recuento de falla electrónica: | No |
|
recuento de falla
electrónica |
0xFFFFFFFF | cada intento fallido aumenta | |||||
| este recuento en uno | |||||||
| 0x0F |
Bloqueo
L/E |
1 | 1 | 0x00 | Deshabilitar Bloqueo automático Sí | ||
| automático | 0xFF | Habilitar Bloqueo automático | |||||
| 0x10 | Longitud del PIN | L/E | 1 | 1 | 0x04 – 0x08 | Longitud del PIN del código de | Sí |
| del código de | usuario, un valor entre 4 y 8 | ||||||
| usuario | (valor predeterminado 4) | ||||||
| 0x11 |
Obtener recuento
R |
4 | 4-Jan | 0x00000000 – | Recuento de transición de | No | |
| de transición de | 0xFFFFFFFF | precarga alta electrónica (un | |||||
| precarga alta | subconjunto de 0x0C anterior): | ||||||
| eléctrica | transiciones ocurridas con | ||||||
| precarga alta | |||||||
| 0x12 | Obtener versión | R | 1 | 1 | 0x00 – 0xFF | Obtener la versión del | No |
| de Bootloader | bootloader |
24352403
Paramètres de configuration et d'association Z-Wave
Serrure à pêne dormant à écran tactile avec alarme | Modèle BE469
Écran tactile branché | Modèle BE468
Cette page décrit les groupes d'association pris en charge et les paramètres de configuration. Cette information est offerte pour les utilisateurs avertis qui souhaitent configurer manuellement ces paramètres.
Information concernant le groupe d'association
La serrure à pêne dormant à écran tactile avec alarme prend en charge un groupe d'association qui peut contenir jusqu'à deux nodes. Ce groupe est le groupe numéro un.
Paramètres de configuration
Le tableau ci-dessous présente les paramètres de configuration pris en charge. Consultez la documentation de votre contrôleur ou de votre passerelle.
|
No de
paramètre |
Descripti
on |
Lect
ure / écriture |
Taille |
Valeur de
configurati on |
Valeur |
Descripti
on de lavaleur |
Associati
on |
|---|---|---|---|---|---|---|---|
| 0x00 – 0x02 | Réservé | S.O. | S.O. | S.O. | S.O. | S.O. | S.O. |
| 0x03 | Avertisseur | L/É | 1 | 1 | 0x00 | Désactiver l'avertisseur | Oui |
| 0xFF | Activer l'avertisseur | ||||||
| 0x04 | Mode Vacances | L/É | 1 | 1 | 0x00 | Désactiver le mode Vacances | Oui |
| 0xFF | Activer le mode Vacances | ||||||
| 0x05 | Verrouillage rapide | L/É | 1 | 1 | 0x00 |
Désactiver le verrouillage
rapide |
Oui |
| 0xFF | Activer le verrouillage rapide | ||||||
| 0x06 |
Champ de bits du créneau
de l'utilisateur (créneaux |
L | 4 | 1 | 0x00 – 0xFF |
Créneaux de l'utilisateur 8 - 1
(MSB – LSB) |
Non |
| utilisés) | 8,7,6,5,4,3,2,1 | ||||||
| 2 | 0x00 – 0xFF |
Créneaux de l'utilisateur 16 -
9 (MSB – LSB) |
|||||
| 16, 15, 14, 13, 12, 11, 10, 9 | |||||||
| 3 | 0x00 – 0xFF |
Créneaux de l'utilisateur 24 -
17 (MSB – LSB) |
|||||
| 24, 23, 22, 21, 20, 19, 18, 17 | |||||||
| 4 | 0x00 – 0xFF |
Créneaux de l'utilisateur 30 -
25 (MSB – LSB) |
|||||
| X, X, 30, 29, 28, 27, 26, 25 | |||||||
| 0x07 | Verrouiller un mode | L/É |
1
1 |
0x00 | Alarme désactivée | Oui | |
|
d'alarme spécifique
BE469 seulement |
0x01 | Alarme | |||||
| 0x02 | Témoin d'intégrité | ||||||
| 0x03 | Accès forcé | ||||||
| 0x04– 0xFF | Réservé | ||||||
| 0x08 | Verrouiller un degré |
L/É
1 |
1 | 0x00 | N'est pas pris en charge | Oui | |
| spécifique de sensibilité | 0x01 | Sensibilité la plus élevée | |||||
| d'alarme | 0x02 | ||||||
| BE469 seulement | 0x03 | Sensibilité moyenne | |||||
| 0x04 | |||||||
| 0x05 | Sensibilité la plus faible | ||||||
| 0x06 – 0xFF | Réservé | ||||||
| 0x09 | Verrouiller un degré | L/É | 1 | 1 | 0x00 | N'est pas pris en charge | Oui |
| spécifique de sensibilité du | 0x01 | Sensibilité la plus élevée | |||||
| témoin d'intégrité | 0x02 | ||||||
| BE469 seulement | 0x03 | Sensibilité moyenne | |||||
| 0x04 | |||||||
| 0x05 | Sensibilité la plus faible | ||||||
| 0x06 – 0xFF | Réservé |
|
No de
paramètre |
Descripti
on |
Lect
ure / écriture |
Taille |
Valeur de
configurati on |
Valeur |
Descripti
on de lavaleur |
Associati
on |
|---|---|---|---|---|---|---|---|
| 0x0A | Verrouiller un degré | L/É | 1 | 1 | 0x00 | N'est pas pris en charge | Oui |
| spécifique de sensibilité de | 0x01 | Sensibilité la plus élevée | |||||
| l'activation de l'alarme | 0x02 | ||||||
| BE469 seulement | 0x03 | Sensibilité moyenne | |||||
| 0x04 | |||||||
| 0x05 | Sensibilité la plus faible | ||||||
| 0x06 – 0xFF | Réservé | ||||||
| 0x0B | Désactivation spécifique | L/É | 1 | 1 | 0x00 | Désactiver la commande | Non |
| de l'alarme de la serrure – | locale (désactive les fonctions | ||||||
| contrôles locaux | d'activation/désactivation | ||||||
| BE469 seulement | de l'alarme locale, de | ||||||
| changement de mode, de | |||||||
| changement de sensibilité) | |||||||
| 0xFF | Activer la commande | ||||||
| locale (active les fonctions | |||||||
| d'activation/désactivation | |||||||
| de l'alarme locale, de | |||||||
| changement de mode, de | |||||||
| changement de sensibilité) | |||||||
| 0x0C | Obtenir le compte du | L | 4 | 1 – 4 | 0x00000000 – | Compte du nombre de | Non |
|
nombre de transitions
électroniques |
0xFFFFFFFF | transitions électroniques | |||||
| – Une transition est un | |||||||
| passage de l'état verrouillé | |||||||
| à déverrouillé ou de l'état | |||||||
| déverrouillé à verrouillé | |||||||
| 0x0D |
Obtenir le compte du
nombre de transitions mécaniques |
L | 4 | 1 – 4 | 0x00000000 – | Compte du nombre de | Non |
| 0xFFFFFFFF | transitions mécaniques – Une | ||||||
| transition est un passage de | |||||||
| l'état verrouillé à déverrouillé | |||||||
| ou de l'état déverrouillé à | |||||||
| verrouillé | |||||||
| 0x0E |
Décompte électronique du
nombre d'échecs |
L | 4 | 1 – 4 |
0x00000000 –
0xFFFFFFFF |
Compte du nombre d'échecs | Non |
| électroniques – chaque | |||||||
| tentative manquée augmente | |||||||
| le décompte de un | |||||||
| 0x0F | Verrouillage automatique | L/É | 1 | 1 | 0x00 | Désactiver le verrouillage | Oui |
| automatique | |||||||
| 0xFF | Activer le verrouillage | ||||||
| automatique | |||||||
| 0x10 | Longueur des codes | L/É | 1 | 1 | 0x04 – 0x08 | Longueur des codes | Oui |
| d'utilisateur | d'utilisateur, une valeur entre | ||||||
| 4 et 8 (4 par défaut) | |||||||
| 0x11 | Obtenir le compte du | L | 4 | 4-Jan | 0x00000000 – | Compte du nombre de | Non |
| nombre de transitions à | 0xFFFFFFFF | transitions électroniques à | |||||
| prétension élevée | prétension élevée – un sous | ||||||
| ensemble du paramètre 0x0C | |||||||
| ci-dessus – transitions qui | |||||||
| surviennent avec prétension | |||||||
| élevée | |||||||
| 0x12 | Obtenir la version du | L | 1 | 1 | 0x00 – 0xFF | Obtenir la version du chargeur | Non |
| chargeur d'amorçage | d'amorçage |