ASSA ABLOY ACCENTRA TJ4410, TJL4410, TJS4410 Door Closer Top Jamb Hold Open Arm with or without 486_7344-0153

Open the original PDF document

View PDF

(143) 5-5/8

4

(44.5) 1-3/4

(111.1) 4-3/8

6-3/4 (314.3)

12-3/8

(171.5)

Opening Dim. "A"
To 100° 7-5/8 (194)
100° to 120° 6-5/8 (168)
120° to 150° 4-5/8 (117)
150° to 180° 4-1/8 (105)

This template covers the following series of door closers:

1400 4410
TJ1400 TJ4410
TJL1400 TJL4410
TJS1400 TJS4410

Caution: Door swing may be limited by door, frame, wall or hardware conditions.

"A" (10) 3/8 * (101.6) (60.3) 2-3/8 Hinge or Pivot 4 Holes for Closer 4 Holes for 486 Backplate or CL

Preparation for Fasteners
Fasteners Door or
Frame
Drill Sizes
d #14 type "A"
S.M. Screw
Wood
ar
d
n
Arm: 1-1/4" (32mm)
Closer: 2-3/4" (70mm)
Aluminum 7/32" (5.5mm)
Sta 1/4-20 machine screw Metal drill: #7 (.201")
tap: 1/4-20
al
n
o
pti
O
Sex nuts and bolts Hollow
Metal
9/32" (7.00mm) thru;
3/8" (9.50mm) on door or
transom face opposite to closer
Aluminum
or Wood
3/8" (9.50mm) thru
Thru bolts and
grommet nuts
All 9/32" (7.00mm) thru;
3/8" (9.50mm) dia. x
3/8" (10mm) deep on door or
transom face opposite to closer

2 Holes for Arm Shoe

(41)

1-5/8 * (29)

1-1/8 *

Notes:

  • 1. Do not scale drawing.
  • 2. Left hand door shown.
  • 3. Dimensions are in inches (mm).
  • 4. Hollow metal doors require channel or box type reinforcement when thru bolt mount is specified.
  • 5. Sex bolts may be required for wood or plastic faced fire door mounting.
  • 6. Minimum thickness recommended for reinforcements in hollow metal doors and frames: 0.1046" (2.66mm) unless otherwise noted.
  • 7. Hold Open Arm closers are not permitted to be used on fire doors.

Copyright © 2004, 2023, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.

(TJ), (TJL), (TJS) 1400 Series Door Closers - Sized 1 thru 6 (TJ), (TJL), (TJS) 4410 Series Door Closers - Multi-Size 2 to 6 With or Without 486 Backplate Top Jamb Hold Open Arm Application

Template Number: 7344-0153 Sheet: 1 of 1

Date: 12/23

(19) 3/4

1-855-557-5078 www.assaabloy.com

* Always use frame or transom rabbet as reference plane, not bottom of stop.