ASSA ABLOY ACCENTRA 550F & 560F Mortise Trim (Discontinued) Installation Instructions_80-8470-0551-000

Open the original PDF document

View PDF

Brandywine 2-11/16 Projection: (68) Copenhagen 3-1/8 Projection: Projection: Projection: Augusta Arcadia Carmel A BR (THRU DOOR) - 4 "X" HOLES -1-1/4 DIA. (32) (OUTSIDE FACE) G Device & Trim) 3/8 (10) DIA. E HORIZONTAL REFERENCE REFERENCE VERTICAL (G Trim) Ш OUTSIDE FACE DOOR \frac{3-5/8}{(92)} 3-5/8 (92)

2-5/16 (59)

Installation Instructions

1. Select template holes required. Cross out holes not needed for mounting trim.

Holes
551(F) X&E
552(F), 556(F) X, D, & E
554(F), 558(F) X&D
561(F) X, Y, & E
562(F) X, Y, Z, & E

Assemble trim. See other side for components and instructions. NOTE: Device - Trim match in Function Chart. (over) ر ا

3-1/16 (78)

nstructions), carry "Vertical Reference Centerline" from inside After marking door inside face for device location (Device door face. Follow steps 3a. and 3b. below. က

  • Carry "Horizontal Reference Centerline" from inside to outside
    • door face. 4.
  • Align trim template and tape to door outside face. CAUTION: Office copiers and facsimile machines may change the size of a drawing and make the template inaccurate to use as a door marker. If this is not the original template packed with the trim, use only the dimensions written on the template to locate the holes on the door (do not use the template as a door marker). Ś
  • Spot holes and prepare door for trim. <u>ශ</u>
  • 7. Mount trim to door (Fig. 1). Fasten finger tight only with 2 or 3 screws (b) and washers (c), seated on door. Thread cylinder positioned as shown. Lock cylinder in place (cylinder set into lock till seated in cylinder ring recess and keyway is screw accessible thru lock front).

<u>2-7/8</u> (73)

Continue as shown in device instructions.

Projection: 2-13/16 (71) Finlandia

\frac{1/2}{(13)} DIA. \times \frac{1/8}{(3)} DEEP

1-1/4 DIA. (32) (OUTSIDE FACE)

\frac{3-1/2}{(89)}

<u></u> စ

(2) Screws and washers holt trim

How Trim Is Used

The device mortise lock determines how the outside trim functions. Identify TRIM and DEVICE in the chart below. Verify that the combination permits the desired access function.

FUNCTION MORTISE
11.00 FEGIVE ANSI DESCRIPTION LOCK
7130K5/E) 551(F), 552(F),
561(F), 562(F)
F03 Key retracts latchbolt. 358/E)
, 100,00(1) 554 F02 Pull to open (dogged device).
554(F) _ Dummy trim (rigid knob).
556(F) F03 Key retracts latchbolt.
7130L5(F) 558 F02 Pull to open (dogged device). 35L(F)
558(F) - Dummy trim (rigid lever).
7130K8/F) 552(F) F08 Key locks/unlocks knob. 38K(E)
554(F) ı Passage (knob always active). 0014(1)
71301 8/E 556(F) F08 Key locks/unlocks lever. 381 (E)
, 10000(1) 558(F) _ Passage (lever always active). טטר(ר)

80-8470-0551-000 (4-96)