ACSI Exit Device Installation Instructions K-103 Switch Kit II-E1500-02
Open the original PDF document
View PDFEXIT DEVICE INSTALLATION INSTRUCTIONS
K-103 SWITCH KIT
SARGENT 80 SERIES EXIT DEVICES, ARROW 1000, 3000 & 4000 SERIES EXIT DEVICES AND DOREX 9500 SERIES EXIT DEVICES SWITCH MONITORS EGRESS BY PUSHBAR ACTIVATION OF EXIT DEVICE
CENTER LINE OF DEVICE CHANNEL
ELECTRICAL SPECIFICATIONS
- SPDT MONITOR SWITCH
- CONTACT RATING: 4 AMP @ 250VAC
COLOR CODE FOR WIRES
- YELLOW WIRE: COMMON
- RED WIRE: NORMALLY OPEN
- GRAY WIRE: NORMALLY CLOSED
SWITCH ARM LOCATED UNDER PUSHBAR PIVOT AS SHOWN
DRILL AND TAP FOR #6-32 THREADED
HOLE TYPICAL 2 PLACES.
INSTALLATION INSTRUCTIONS
STEP 1: REMOVE END COVER FROM CHANNEL.
STEP 2: LOCATE CENTER OF CHANNEL, THEN MARK DIMENSIONS AS SHOWN.
STEP 3: AFTER DIMENSIONS ARE MARKED CENTER PUNCH FOR 2 DRILL HOLES.
USE A #36 (.106 DIA.) DRILL BIT FOR PROPER TAP DRILL SIZE.
STEP 4: DRILL HOLES FOR BRACKET, NEXT USING A #6-32 TAPER TAP, TAP THE 2 HOLES.
STEP 5: DEBURR HOLES SO THAT BRACKET WILL SIT FLAT.
STEP 6: DEPRESS PUSHBAR THEN MAKE SURE THAT SWITCH ARM IS LOCATED UNDER END OF PIVOT,
THEN SECURE BRACKET WITH PROVIDED HARDWARE.
STEP 7: SWITCH SHOULD FUNTION AS FOLLOWS: SWITCH ARM SHOULD BE ACTIVATED WHEN PUSHBAR IS IN RELAXED POSITION.
SWITCH ARM SHOULD DE-ACTIVATE WHEN PUSHBAR IS DEPRESSED.
STEP 8: MOUNT DEVICE, TERMINATE WIRES ACCORDINGLY WITH PROPER WIRE NUTS OR CRIMPS.
5/16"