3101C Series Delay Egress 1500 Lbs. HF
Open the original PDF document
View PDFDelayed Egress Systems
3101C (Gen II) CSFM
Delay egress electromagnetic locks, surface mounted for outswing single or double doors and inswing single doors. Non-handed.
Sizes: 3"D x 2-3/4"H x 11"L (3101C) 3"D x 2-3/4"H x 22"L (3121C) 3"D x 2-3/4"H x 11"L ea. (3121C2) 2-3/4"D x 4"H x 11"L (3101C-TJ101)
Multi-voltage auto-sensing 12/24 VAC/VDC
Current Draw: 456 mA @ 12VDC / 263 mA @ 24VDC (3101C, 3101C-TJ101)
849 mA @ 12VDC / 480 mA @ 24VDC (3121C, 3121C2)
| MODEL | PRODUCT | FINISH | WEIGHT |
|---|---|---|---|
| 3101C-G2 | Single Delay Egress Lock Outswing | US28 | 12 Lbs. |
|
3121C-G2
3121C2-G2 |
Double Delay Egress Lock Pair Outswing
Double Delay Egress Lock Pair Outswing |
US28
US28 |
24 Lbs.
24 Lbs. |
|
Tandem Unit To Accommodate Center Mullion
3101C-TJ101-G2 Single-Inswing Delay Egress Lock Kit Includes "Z" Bracket, Shim Plate, Door Sign, |
US28 | 15 Lbs. | |
| Wall-Mount Keyswitch (#7054) |
3121C2 (Gen II) CSFM
OPTIONS
•
*
Auxiliary Alarm Output - Redundant 2nd delay egress output, SPDT. Anti-Tamper Switch - Signals removal of the housing cover. AAO ATS
Anti-Tamper Switch - For the 3121C and 3121C2 Bypass Monitor - Signals bypass keyswitch activation Door Status Switch - Signals door closed or ajar. Door Status Switch - For the 3121C and 3121C2. ATS2 BPM DSM DSM2
Dynastat Force Sensor - Indicates efficient magnetic bond. Dynastat Force Sensor - For the 3121C and 3121C2. Egress Sensor Omitted - For externally triggered egress. Keyswitch Omitted - In favor of separate remote keyswitch. (Suggested for door heights over 8 ft.) See page 47. DYN DYN2 ETR KSO
Low Power Consumption Coil - 12V only (Single Lock) Low Power Consumption Coils - 12V only (Double lock) Special Finish - Standard finish US28. Special anodized finishes see page 56. LP LP2 SF
3101C-TJ101 (Gen II)
BUILDING CODE SOFTWARE OPTIONS (FACTORY INSTALLED)
| BOCA | For operation in compliance with BOCA Code. |
|---|---|
| UBC | For operation in compliance with UBC Code. |
| CHGO | For operation in compliance with Chicago Building Code. |
Notes: • BPM option not available with the KSO option.
* LP option may not be combined with DYN option.
3101C SERIES COMMON REPLACEMENT PARTS
| 300477 | Door Sign only, 15 second delay verbiage. | |
|---|---|---|
| 300478 | Door Sign only, 30 second delay verbiage. | |
| 301393 | Egress Sensor Adjustment Wheel Kit. | |
| 301424 | "PULL" Door Sign, 3101C-TJ101-G2. | |
| 301556 | Mounting Hardware Kit, 3101C-G2. | |
| 301047 | Ribbon Interconnect Cable, 12" Length, 3121C-G2. | |
| 301048 | Ribbon Interconnect Cable, 36" Length, 3121C2-G2. | |